S2600GZ and S2600GL

Table Of Contents
Intel® Server Board S2600GZ/GL TPS BIOS Setup Utility
Once selected and set up (if necessary), individual bootable logical or physical drives available on the
selected controller will be listed in the Bootable Devices menu display.
If only one device selects RSTe, it will be available as a boot device along with any other devices this
option is only necessary to distinguish between which RSTe device runs the Option ROM instance.
BIOS is required to designate the OPROM for the boot device selected here. Two iterations of the
OPROM cannot fully load simultaneously, and the version fully loaded will only show devices
connected to the given controller, so the OPROM load order is based on BIOS selecting the correct
device.
Note: If RSTe is selected, then only one CONTROLLER can be bootable, so there will be situations
where the boot drive *OR* an optical device will be bootable, but not both.
Please also see the product System Guide for restrictions on expander boot support.
Back to [Mass Storage Controller Configuration Screen
]
Intel
®
Storage Module
Option Values: None
<Name of Storage Module detected>
Names of Storage Modules supported at this time are:
Intel
®
Integrated RAID Module
Intel
®
Integrated RAID Module RMS25PB040
Intel
®
Integrated RAID Module RMT3PB080
Intel
®
Integrated RAID Module RMS25CB080
Intel
®
Integrated RAID Module RMS25CB040
Intel
®
Integrated RAID Module RMT3CB080
Intel
®
Integrated RAID Module RMS25JB080
Intel
®
Integrated RAID Module RMS25JB040
Intel
®
Integrated RAID Module RMS25KB080
Intel
®
Integrated RAID Module RMS25KB040
Help Text: <None>
Comments: Information only. If no Intel
®
Storage Module is detected, then None is displayed.
This shows the customer the product name of the module installed, which helps in identifying drivers,
support, documentation, and so on
Back to [Mass Storage Controller Configuration Screen]
SATA Port
(For Port numbers 0-6)
Option Values: Not Installed
<Drive Information>
Help Text: <None>
Comments: Information only. The Drive Information, when present, will typically consist of the
drive model identification and size for the disk drive installed on a particular port.
This Drive Information line is repeated for all 6 SATA Port for the onboard AHCI capable SATA
Controller. However, for any given board, only the ports which are physically populated on the board
are shown. That is, a board which only implements the two 6 GB/s ports 0 and 1 will only show those
two ports in this Drive Information list.
This section for Drive Information does not appear at all when the SCU is set to Disabled or the SATA
operational mode is RAID Mode, nor for any drives attached to the SCU SATA or SAS ports. In these
cases the BBS information is not available to display.
Revision 2.4