Technical Product Specification

Intel® Server Boards S4600LH2/T2 TPS Appendix C: Management Engine Generated SEL Event Messages
Revision 2.0
229
support>
Table 69. Node Manager Health Event
Node Manager Health
Event
Request
Byte 1
- EvMRev
=04h (IPMI2.0 format)
Byte 2
Sensor Type
=DCh (OEM)
Byte 3
Sensor Number
(Node Manager Health sensor)
Byte 4
Event Dir | Event Type
[0:6]
Event Type
= 73h (OEM)
[7]
Event Dir
=0 Assertion Event
Byte 5
Event Data 1
[0:3]
Health Event Type
=02h
Sensor Node Manager
[4:5]=10b
OEM code in byte 3
[6:7]=10b
OEM code in byte 2
Byte 6
Event Data 2
[0:3]
Domain Id (Currently, supports only one domain,
Doma
in 0)
[4:7]
Error type
=0
-9 - Reserved
=10
Policy Misconfiguration
=11
Power Sensor Reading Failure
=12
Inlet Temperature Reading Failure
=13
Host Communication error
=14
Real-time clock synchronization failure
=15
Reserved
Byte 7
Event Data 3
if error indication = 10 <PolicyId>
if error indication = 11 <PowerSensorAddress>
if error indication = 12 <InletSensorAddress>
Otherwise set to 0.