Technical Product Specification
Intel® Server Boards S4600LH2/T2 TPS Appendix C: Management Engine Generated SEL Event Messages
Revision 2.0
229
support>
Table 69. Node Manager Health Event
Node Manager Health
Event
Request
Byte 1
- EvMRev
=04h (IPMI2.0 format)
Byte 2
– Sensor Type
=DCh (OEM)
Byte 3
– Sensor Number
(Node Manager Health sensor)
Byte 4
– Event Dir | Event Type
[0:6]
– Event Type
= 73h (OEM)
[7]
– Event Dir
=0 Assertion Event
Byte 5
– Event Data 1
[0:3]
– Health Event Type
=02h
– Sensor Node Manager
[4:5]=10b
– OEM code in byte 3
[6:7]=10b
– OEM code in byte 2
Byte 6
– Event Data 2
[0:3]
– Domain Id (Currently, supports only one domain,
Doma
in 0)
[4:7]
– Error type
=0
-9 - Reserved
=10
– Policy Misconfiguration
=11
– Power Sensor Reading Failure
=12
– Inlet Temperature Reading Failure
=13
– Host Communication error
=14
– Real-time clock synchronization failure
=15
– Reserved
Byte 7
– Event Data 3
if error indication = 10 <PolicyId>
if error indication = 11 <PowerSensorAddress>
if error indication = 12 <InletSensorAddress>
Otherwise set to 0.