Technical Product Specification
Appendix B: Integrated BMC Sensor Tables Intel® Server Boards S4600LH2/T2 TPS
Revision 2.0
220
PCI Riser 2
Temperature
(PCI Riser 2 Temp)
2Ch
Platform-
specific
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X
SAS Module
Temperature
(SAS Mod Temp)
2Dh
Platform-
specific
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X
Exit Air Temperature
(Exit Air Temp)
2Eh
Chassis &
Platform
Specific
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X
Network Interface
Controller Temperature
(LAN NIC Temp)
2Fh All
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X
Fan Tachometer
Sensors
(Chassis specific
sensor names)
30h–
3Fh
Chassis &
Platform
Specific
Fan
04h
Threshol
d
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatalNote2
As
and
De
Analo
g
R, T M -
Fan Present Sensors
(Fan x Present)
40h–
4Fh
Chassis &
Platform
Specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As
and
De
-
Triggered
Offset
Auto -
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As
and
De
–
Trig
Offset
A X
01 - Failure
Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration
error
OK
Power Supply 2 Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As
and
De
–
Trig
Offset
A X
01 - Failure
Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration
error
OK