Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel® Server Boards S4600LH2/T2 TPS
Revision 2.0
218
05 - Non-
redundant:
insufficient
resources.
Non-Fatal
06 Non-
Redundant:
degraded from
fully redundant.
Degraded
07 - Redundant
degraded from
non-redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperatu
re
01h
Digital
Discrete
03h
01 State
Asserted
Fatal
As
and
De
Trig
Offset
M X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Bo
ard
15h
Digital
Discrete
08h
01
Inserted/Present
OK
As
and
De
Trig
Offset
M X
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Bo
ard
15h
Digital
Discrete
08h
01
Inserted/Present
OK
As
and
De
Trig
Offset
M X
BMC Firmware Health
(BMC FW Health)
10h All
Mgmt
Health
28h
Sensor
Specific
6Fh
04 Sensor
Failure
Degraded
As -
Trig
Offset
A X
System Airflow
(System Airflow)
11h All
Other
Units
0Bh
Threshol
d
01h
Analo
g
Baseboard Temperature
1
(Platform Specific)
20h
Platform-
specific
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X
Front Panel
Temperature
(Front Panel Temp)
21h All
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X
SSB Temperature
(SSB Temp)
22h All
Temperatu
re
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As
and
De
Analo
g
R, T A X