Technical Product Specification

Intel® Server Boards S4600LH2/T2 TPS
Revision 2.0
180
13. Plug & Play BMC Detection
Option Values: Enabled
Disabled
Help Text:
If enabled, the BMC will be detectable by OSes which support plug and play loading of an IPMI
driver. Do not enable this option if your OS does not support this driver.
Comments: This option controls whether the OS Server Management Software will be able to
find the BMC and automatically load the correct IPMI support software for it. If your OS does not
support Plug & Play for the BMC, you will not have the correct IPMI driver software loaded.
Back to [Server Management Screen
]
EuP LOT6 Off-Mode
Option Values: Enabled
Disabled
Help Text:
Enable/disable Ecodesign EuP LOT6 “Deep Sleep” Off-Mode for near-zero energy use when
powered off.
Comments: This option controls whether the system goes into “Deep Sleep” or more
conventional S5 “Soft-Off” when powered off. Deep Sleep” state uses less energy than S5, but S5 can
start up faster and can allow a Wake on LAN action (which cannot be done from a Deep Sleep state).
This option will not appear on platforms which do not support EuP LOT6 Off-Mode.
Back to [Server Management Screen
]
14. Shutdown Policy
Option Values: Enabled
Disabled
Help Text: Enable/Disable Shutdown Policy.
Comments: This option is designed for multiple-node system and to control the policy that
BMC should shutdown one node if it detected over-current or over-temperature condition. The BIOS
and the BMC will synchronize the policy during the BIOS POST and current value of the BMC will be
displayed in BIOS Setup.
This option is only displayed when the BMC support this feature on the node.
Back to [Server Management Screen]
15. Console Redirection
Option Values: <None>
Help Text: View/Configure Console Redirection information and settings.
Comments: Selection only. Position to this line and press the <Enter> key to go to the
Console Redirection group of configuration settings.
Back to [Server Management Screen
]