Technical Product Specification

Intel® Server Boards S4600LH2/T2 TPS
Revision 2.0
146
There are two types of onboard controller configured in this screen, the AHCI SATA controller and the Storage
Control Unit (SCU) with SATA or SAS drive support and RAID support. There are also informational displays of
AHCI and SCU controller configuration, and SATA Drive Information when applicable. If the presence of an
Intel
®
Storage Module is detected, the type of Storage Module is displayed as information-only.
To access this screen from the Main screen, select Advanced > Mass Storage Controller Configuration. To
move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired
screen.
Advanced
Mass Storage Controller Configuration
AHCI Controller Configuration
<AHCI Port Configuration>
SATA/SAS Controller Configuration
<SCU SAS/SATA Port Configuration>
AHCI Capable SATA Controller
Disabled/Compatibility/Enhanced/AHCI/RAID Mode
AHCI eSATA Options
SATA/eSATA
AHCI HDD Staggered Spin-Up
Enabled/Disabled
AHCI Capable RAID Options
INTEL(R) ESRT2 (LSI*)/INTEL(R) RSTe
SAS/SATA Capable Controller
Disabled/INTEL(R) ESRT2 (LSI*)/INTEL(R) RSTe
RSTe Boot Configuration
Neither/AHCI Capable Ctrlr/SAS/SATA Capable Ctrlr
Intel® Storage Module
- None/<Name of storage module detected >
SATA Port 0
Not Installed/<Drive Information>
SATA Port 1
Not Installed/<Drive Information>
SATA Port 2
Not Installed/<Drive Information>
SATA Port 3
Not Installed/<Drive Information>
SATA Port 4
Not Installed/<Drive Information>
SATA Port 5
Not Installed/<Drive Information>
Figure 36. Mass Storage Controller Configuration Screen
Screen Field Descriptions:
AHCI Controller Configuration
Option Values: <AHCI Port Configuration>
One of these strings:
Controller is disabled
2 ports of 6Gb/s SATA
2 ports of 6Gb/s SATA & 4 ports of 3Gb/s SATA
Help Text: <None>