Monthly Specification Update

Monthly Specification Update Platform Collaboration and Systems Division
6
8.
BMC continuously sends HDD assert/de-assert event during HDD RAID
rebuild under ESRT2 mode of the SCU controller
Problem HDD fault will keep asserting and de-asserting frequent during RAID rebuild
under ESRT2.
Implication During HDD ESRT2 RAID rebuild, there's flood HDD fault assert/deassert(SAS
RAID) or Rebuild/remap (SATA RAID) logs into SEL.
Status This issue was fixed in ESRT2 driver 15.00.0528.2012 and later version.
Workaround None.
9.
Intel® RAID C600 Upgrade Key replacement Issue
Problem With Manageability Engine (ME) Firmware 02.01.05.069, the server may detect
the incorrect Storage Control Unit (SCU) Redundant Array of
Inexpensive/Independent Disks (RAID) information after installing or replacing
the RAID upgrade key. The board or system may still show the previous RAID
information even if you replace the key with a new one.
Implication With the ME firmware 02.01.05.069, the system may not detect the new RAID
activation key during the first time AC power on.
Status The issue was fixed in ME firmware 02.01.05.091 and later version.
Workaround None.
10.
Intel® LAN driver installation failure on Windows* 7
Problem The Intel® LAN driver version 16.8 and below may not be installed sucessfully
on Windowns* 7 with the .bat installation scripts in the driver package.
Implication The LAN driver can not be installed by the .bat installation scripts in the driver
package.
Status The issue was fixed in Intel® LAN driver 17.1 and later version.
Workaround None