Technical Product Specification
Table Of Contents
- 1. Introduction
- 2. Product Family Overview
- 3. Power Subsystem
- 3.1 Mechanical Overview
- 3.2 Power Connectors
- 3.3 Power Supply Module Efficiency
- 3.4 AC and DC Power Cord Specification Requirements
- 3.5 AC Input Specifications
- 3.5.1 Power Factor
- 3.5.2 AC Input Voltage Specification
- 3.5.3 AC Line Isolation Requirements
- 3.5.4 AC Line Dropout/Holdup
- 3.5.5 AC Line Fuse
- 3.5.6 AC Inrush
- 3.5.7 AC Line Transient Specification
- 3.5.8 Susceptibility Requirements
- 3.5.9 Electrostatic Discharge Susceptibility
- 3.5.10 Fast Transient/Burst
- 3.5.11 Radiated Immunity
- 3.5.12 Surge Immunity
- 3.5.13 Power Recovery
- 3.5.14 Voltage Interruptions
- 3.5.15 Protection Circuits
- 3.5.16 Over-current Protection (OCP)
- 3.5.17 Over-voltage Protection (OVP)
- 3.5.18 Over-temperature Protection (OTP)
- 3.6 1600W DC Power Supply Support
- 3.6.1 Power Supply Module Efficiency
- 3.6.2 DC Inlet Connector
- 3.6.3 DC Input Voltage Specification
- 3.6.4 DC Holdup/Dropout Time
- 3.6.5 DC Line Fuse
- 3.6.6 DC Inrush
- 3.6.7 DC Line Surge Voltages (Line Transients)
- 3.6.8 Residual Voltage Immunity in Standby Mode
- 3.6.9 Protection Circuits
- 3.6.10 Over Temperature Protection (OTP)
- 3.7 Cold Redundancy Support
- 3.8 Closed Loop System Throttling (CLST)
- 3.9 Smart Ride Through (SmaRT)
- 3.10 Power Supply Status LED
- 4. Thermal Management
- 5. System Storage and Peripheral Drive Bays Overview
- 6. Storage Controller Options Overview
- 7. Front Control Panel and I/O Panel Overview
- 8. Intel® Local Control Panel
- 9. PCI Riser Card Support
- 10. Additonal System Boards
- 11. Front Panel
- 12. IO Module Support
- 13. Intel® Intelligent Power Node Manager (NM)
- Appendix A: Integration and Usage Tip
- Appendix B: POST Code Diagnostic LED Decoder
- Appendix C: POST Code Errors
- Glossary
- Reference Documents

Intel® Server System R2000LH2/T2 Product Family TPS Appendix A: Integration and Usage Tip
Revision 1.0
97
Appendix A: Integration and Usage Tip
This section provides a list of useful information that is unique to the Intel
®
Server System
R2000LH2/LT2 Product Family and should be kept in mind while configuring your server
system.
Only the Intel
®
Xeon
®
processor E5-4600 product family is supported in this Intel server
system. Previous generation Intel
®
Xeon
®
processors are not supported.
For best system performance, follow memory population guidelines as specified in the
Intel
®
Server Board S4600LH2/S4600LT2 Technical Product Specification.
For best system performance, follow all thermal configuration guidelines as specified in
this document.
The CPU-1 processor and CPU heat sink must be installed first. The CPU-2, CPU-3,
and CPU-4 heat sinks must be installed at all times, with or without a processor installed.
The Mini-SAS connector labeled SCU_1(4-7) on the server board is only functional when
an appropriate Intel
®
RAID C600 Upgrade Key is installed.
Many integrated on-board SAS and RAID options are available by installing any of
several available Intel
®
RAID C600 Upgrade Keys.
The FRUSDR utility must be run after the hardware integration is complete in order to
load the proper Sensor Data Records for the server chassis onto the server board.
Make sure the latest system software is loaded on the server. This includes System
BIOS, BMC Firmware, ME Firmware and FRUSDR. The latest system software can be
downloaded from the Intel web site.