S2600GZ and S2600GL

Table Of Contents
On-board Connector/Header Overview Intel® Server Board S2600GZ/GL TPS
8.4
Fan Connectors
The server board provides support for six system fans. Each 10-pin connector is monitored and controlled by
on-board platform management. On the server board, each system fan connector is labeled “SYS_FAN #”,
where # = 1 thru 6. The following table provides the pin-out for all six system fan connectors.
Table 46. System Fan Connector Pin-out ("SYS_FAN #")
SYS_FAN 1
SYS_FAN 2
SYS_FAN 3
Signal Description
Pin#
Signal Description
Pin#
Signal Description
Pin#
FAN_TACH1_IN
1
FAN_TACH3_IN
1
FAN_TACH5_IN
1
FAN_BMC_PWM0_R_BUF
2
FAN_BMC_PWM1_R_BUF
2
FAN_BMC_PWM2_R_BUF
2
P12V_FAN
3
P12V_FAN
3
P12V_FAN
3
P12V_FAN
4
P12V_FAN
4
P12V_FAN
4
FAN_TACH0_IN
5
FAN_TACH2_IN
5
FAN_TACH4_IN
5
GROUND
6
GROUND
6
GROUND
6
GROUND
7
GROUND
7
GROUND
7
FAN_SYS0_PRSNT_N
8
FAN_SYS1_PRSNT_N
8
FAN_SYS2_PRSNT_N
8
LED_FAN_FAULT0_R
9
LED_FAN_FAULT1_R
9
LED_FAN_FAULT2_R
9
LED_FAN0
10
LED_FAN1
10
LED_FAN2
10
SYS_FAN 4
SYS_FAN 5
SYS_FAN 6
Signal Description
Pin#
Signal Description
Pin#
Signal Description
Pin#
FAN_TACH7_IN
1
FAN_TACH9_IN
1
FAN_TACH11_IN
1
FAN_BMC_PWM3_R_BUF
2
FAN_BMC_PWM4_R_BUF
2
FAN_BMC_PWM5_R_BUF
2
P12V_FAN
3
P12V_FAN
3
P12V_FAN
3
P12V_FAN
4
P12V_FAN
4
P12V_FAN
4
FAN_TACH6_IN
5
FAN_TACH8_IN
5
FAN_TACH10_IN
5
GROUND
6
GROUND
6
GROUND
6
GROUND
7
GROUND
7
GROUND
7
FAN_SYS3_PRSNT_N
8
FAN_SYS4_PRSNT_N
8
FAN_SYS5_PRSNT_N
8
LED_FAN_FAULT3_R
9
LED_FAN_FAULT4_R
9
LED_FAN_FAULT5_R
9
LED_FAN3
10
LED_FAN4
10
LED_FAN5
10
8.5
Serial Port Connectors
The server board includes two serial port connectors.
Serial-B is an internal 10-pin DH-10 connector labeled “Serial_B” and has the following pin-out.
Table 47. Serial-B Connector Pin-out
Signal Description
Pin#
Pin#
Signal Description
DCD
1
2
DSR
SIN
3
4
RTS
SOUT
5
6
CTS
DTR
7
8
RI
GROUND
9
KEY
Serial-A is an external RJ45 type connector and has the following pin-out configuration.
Revision 2.4