S2600GZ and S2600GL

Table Of Contents
Intel® Server Board S2600GZ/GL TPS Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Readi
ng Type
Event Offset Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Of
fsets
Event
Data
Rearm
Stand-
by
Processor 1 ERR2 Timeout
(P1 ERR2)
7Ch All
Processor
07h
Digital
Discrete
03h
01 State Asserted fatal
As
and
De
Trig Offset A
Processor 2 ERR2 Timeout
(P2 ERR2)
7Dh All
Processor
07h
Digital
Discrete
03h
01 State Asserted fatal
As
and
De
Trig Offset A
Catastrophic Error
(CATERR)
80h All
Processor
07h
Digital
Discrete
03h
01 State Asserted fatal
As
and
De
Trig Offset M
Processor0 MSID Mismatch
(P0 MSID Mismatch)
81h All
Processor
07h
Digital
Discrete
03h
01 State Asserted fatal
As
and
De
Trig Offset M
Processor Population Fault
(CPU Missing)
82h All
Processor
07h
Digital
Discrete
03h
01 State Asserted Fatal
As
and
De
Trig Offset M
Processor1 MSID Mismatch
(P1 MSID Mismatch)
87h All
Processor
07h
Digital
Discrete
03h
01 State Asserted fatal
As
and
De
Trig Offset M
Processor 1 VRD
Temperature
(P1 VRD Hot)
90h All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As
and
De
Trig Offset M
Processor 2 VRD
Temperature
(P2 VRD Hot)
91h All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As
and
De
Trig Offset M
Processor 1 Memory VRD
Hot 0-1
(P1 Mem01 VRD Hot)
94h All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As
and
De
Trig Offset A
Processor 1 Memory VRD
Hot 2-3
(P1 Mem23 VRD Hot)
95h All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As
and
De
Trig Offset A
Revision 2.4
205