Specifications
Monthly Specification Update
Workaround None.
27.
The Intel® Xeon Phi™ Coprocessor PCI Express* Card sensors numbering
may not be consistent with riser slot numbering
Problem The Intel® Xeon Phi™ Coprocessor PCI Express* Card (MIC card) sensors
numbering may not be consistent with riser slot numbering on the server board.
When an Intel® Xeon Phi™ Coprocessor PCI Express* Card is installed in the
server system, in Intel® Integrated BMC Web Console, the card sensor may
show “MIC 2 Status” and “MIC 2 Margin” if the card is installed on “RISER
SLOT_1” and “MIC 1 Status” and “MIC 1 Margin” if the card is installed on
“RISER SLOT_2”.
Implication Users need to read MIC 2 sensors for a card installed on “RISER SLOT_1” and
read MIC 1 sensors for a card installed on “RISER SLOT_2”. There is no
functional impact on the server system.
Status This issue was fixed in BMC 01.20.5446 and later releases.
Workaround None.
28.
The Activity/Link LED of the Intel
®
I/O Expansion Modules may not be
solid green
Problem The Activity/Link LED (on the left side) of the following Intel
®
I/O Expansion
Modules may not be solid green when there is active connection:
Dual Port Intel® X540 10GbE I/O Module AXX10GBTWLIOM and
AXX10GBTWLHW
Dual Port Intel® 82599 10GbE I/O Module AXX10GBNIAIOM
Implication The LED may keep off instead of solid green. Users can’t figure out whether an
active connection is established through LED behavior.
Status This issue was fixed with new EEPROM cut in at factory, see PCN112163 for
more details.
Workaround None.
13