Specifications
Monthly Specification Update
Workaround None.
22.
POST Code Diagnostic LEDs may not be all off after POST has completed
Problem The POST Code Diagnostic LEDs should be all off after POST has completed.
But the LEDs may show other values after booting to an Operating System.
The codes seen could change at any time after POST or have any value. A
POST code of “0xD4” has been observed after Microsoft* Windows* Server
2008 R2 completes loading. There is no functional impact associated with the
POST code pattern “0xD4”.
Implication The POST Code Diagnostic LEDs may not be all off after POST has completed.
Status This issue was fixed in BMC 01.17.4151 and later release.
Workaround None.
23.
System only reports the first occurrence of power redundancy lost
events
Problem The integrated platform management subsystem will only report the first
occurrence of a power redundancy lost event. Any additional power
redundancy lost events that may occur after the initial event, will not be
reported unless an AC cycle of the server is performed.
Implication With the first power redundancy lost event detected, the system status LED will
change the state to flashing Green and the system event log will display the
event as shown below.
Power Unit, Pwr Unit Redund (#0x2) Informational event: Pwr Unit Redund
reports full redundancy has been lost. Integrated BMC -
LUN#0 (Channel#0)
After hot swapping the faulty power supply, which would change the state of
the system back to normal (system status LED goes back to solid Green), the
system will NOT report any further power redundancy lost events, until an AC
cycle of the server is performed.
Status This issue was fixed in BMC 01.17.4151 and later release.
Workaround None.