Specifications

Monthly Specification Update
[1920x1200,High Color(16bit), 60 Hertz]
Status This issue was fixed in BMC 01.16.4010 and later release.
Workaround None.
19.
Hard drive locate LED may not instantly respond to the locate command
if backplane is connected through SAS expander to a RAID controller
Problem If backplane is connected through SAS expander to a RAID controller, the hard
drive locate LED may not instantly respond to the locate command from the
RAID controller. The LED may blink after up to 2 minutes.
Implication The symptom doesn’t happen if backplane is directly connected to the RAID
controller. Root cause has been identified in the motherboard BMC.
Status This issue was fixed in BMC 01.04.2896 and later release.
Workaround None.
20.
Integrated BMC Web Console Sensor Readings Page Memory
Throttling sensor status will stay “Critical” once triggered
Problem When Memory Throttling is triggered, the Memory “P1 MTT and/or P2 MTT”
sensor status will stay at “Critical” status in the Integrated BMC Web Console
even after throttling has stopped.
Implication User may observe Memory “P1 MTT and/or P2 MTT” status as “Critical” even
when there is no throttling. No functional impact to the system.
Status This issue fixed from ME 02.01.07.328 release.
Workaround Need a AC cycle or reset ME through IPMI to reset the MTT sensor status.
21.
WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS
Problem With Intel
®
LAN driver version 17.1, WOL (Wake on LAN) may not function
under Red Hat* Linux 6.2 64bit OS.
Implication You may not be able to wake system through onboard NIC port.
Status This issue was fixed in LAN driver 17.4 and later release.