Specifications

Monthly Specification Update
4.
HDD status LEDs do not function under specific configuration
Problem If drives are connected through expander to SCU ports and configured under
RSTe mode, the HDD status LEDs may not function properly.
Implication HDD status LED may not show the HDD locate, HDD fault or RAID rebuild
message.
Status This issue was fixed in RSTe driver 3.2.0.1134 and later version.
Workaround None.
5.
RSTe GUI installation may fail if there are no devices attached to any
onboard AHCI ports
Problem When Microsoft Windows 2008* R2 is installed on SCU ports, the installation of
RSTe drivers and the Graphic User Interface (GUI) in Windows 2008* R2 will
fail, if the AHCI controller is enabled while no device is attached to the AHCI
SATA ports.
Implication User may not be able to install RSTe GUI under mentioned configuration when
the AHCI controller is enabled and no devices are attached to the AHCI SATA
ports.
Status This issue was fixed in BIOS 01.03.0002 and later release.
Workaround None.
6.
BMC continuously sends RAID volume rebuild event in RSTe mode of the
SCU controller
Problem When RSTe RAID is in degraded mode and a drive is inserted to start the
RAID rebuild, System Event Log (SEL) records drive plug and rebuild events
and then continuously sends a rebuild event message.
Implication User may see the SEL flooded with RAID volume rebuild event entries.
Status This issue was fixed in latest RSTe driver ver 3.0.0.3020 upd 2012.03.03.
Workaround None.
5