Specifications

Hardware Installations and Upgrades
Intel
®
Server System R2000BB Service Guide 49
Figure 73. Removing the Intel
®
RAID Smart Battery
Replacing the Power Supply
Caution: The power supply is only hot-swappable if you have a redundant system with two power
supplies installed. If you only have one power supply installed, before removing or replacing the
power supply, you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the power cord from the
system or wall outlet.
The power supply can be replaced if it fails. To replace the power supply, follow these steps:
1. Do one of the following:
- If a filler panel is installed, use the 'finger hole' to remove the filler panel (see letter “A”).
-
Figure 74. Removing the filler panel
- If a power supply is installed, push the green latch in the direction shown while pulling out
of the system by the handle.