Technical Product Specification
Intel
®
Local Control Panel Intel
®
Server System R1000SP Product Family TPS
52 Intel Order Number G64249-002 Revision 2.0
event occurs that results in the system status LED to blink green, then the LCD must display the
degraded event that triggered the systems status LED to blink.
Figure 46. LCP Background color during normal operation
Figure 47. LCP Background color during an error
If the user presses any button after the system is powered on, then the main menu will be
displayed. The main menu contains Error, View, and Config items. Based on the user’s
selection, respective sub menu items will be displayed. At any point of time, if there is no user
intervention for more than 10 min, a default banner (if there is no active error event in the
system) or an error event will be displayed.
The following sections discuss the individual menu items. In the following sections, it is
assumed that no active event exists during the LCD display. If any event (fatal or non-fatal)
occurs that degrades the system’s performance, the color of the LCD background turns into light
amber. Even though all the contents (full text) are shown in the example screen shots in the
following sections, by default, only the first 18 characters are displayed when a particular menu
item is selected. The remaining text can be viewed by using right or left buttons.
9.2
Main Menu
If the user presses any button, when the Banner/Error screen is displayed, the following main
menu will get displayed. Using left and right scroll buttons, the curser can be moved under any
one of the following four menu items.
Figure 48. LCP Main Menu
If the user selects menu item, ^, then the LCD displays the previous screen, that is,
Banner/Error string. Selecting the menu item means, moving the cursor under that item using
left or right buttons and pressing enter button subsequently. In all the following sections (or for
any screen shot), if the user clicks the Enter button, when the curser is under the symbol, ^, it
takes to the previous screen. Selection of any of the menu items; Event, View, or Config, leads
the display to their corresponding screen shots and the details of these screen shots are given
in the following sections.
9.3
Event Menu
The LCD displays all active error events in human readable text in chronological order.
Informational events will not be displayed. There is no upper limit on the number of active
events which can be displayed. The severity of the event will be indicated as either Degraded,
Non-Fatal or Fatal.
Figure 49. LCP Event Menu
The menu items, <- and -> are used to traverse among the events. Selection of the menu item,
<-, displays the previous event and the item, ->, displays the next event in human readable
Banner
Error
^ | Event | View | Config
^ | <- | -> | <Error – 1>