Specification Update
Monthly Specification Update
7
10. Integrated BMC Web Console – Power Control page – Perform Action
button not functional.
Problem After performing a Graceful shutdown from the Integrated BMC Web Console
Power Control page the Perform Action button gets grayed out and cannot be
pressed to request another action.
Implication You cannot perform a power on of the system.
Status This issue is fixed in BMC release 1.10.r3560 and later version
Workaround Select another page in the Integrated BMC Web Console and then return to the
Power Control Page. The Perform Action button will then be available.
11. IPMI Get Chassis Status command returns incorrect Chassis Identify
State.
Problem When a Get Chassis Status command is issued, after the Chassis Identify LED
has been forced on, the status of off (00b) is returned for Chassis Identify State
(response data byte 4 – bits [5:4]).
Implication Unable to correctly read when the Chassis Identify LED is on.
Status This issue is fixed in BMC release 1.10.r3560 and later version
Workaround None
12. The BIOS and ME Firmware can't be updated successfully using Intel
®
One Boot Flash Update Utility (OFU) under SuSE* Linux Enterprise
Server 11 (64-bit) with SP2
Problem OFU will fail to update BIOS & ME under SuSE* Linux Enterprise Server 11
(64-bit) with SP2 Operating System.
Implication If the system is running SuSE* Linux Enterprise Server 11 (64-bit) with SP2
Operating System, using OFU to update System Firmware Update Package
(SFUP) will fail.
Status This issue is fixed in OFU Version 11.0 Build 8.
Workaround Update System Firmware Update Package (SFUP) from EFI environment using
iFlash32, FWPIAUpdate and FRUSDR Utility.