Comments: This specifies the IP Source for IPv4 addressing for the Baseboard LAN. There is
a separate IP Source field for the Intel
®
RMM4 LAN configuration.
When IPv4 addressing is used, the initial value for this field is acquired from the BMC, and its setting
determines whether the other Baseboard LAN IPv4 addressing fields are display-only (when Dynamic)
or can be edited (when Static).
When IPv6 addressing is enabled, this field is grayed out and inactive.
Back to [BMC LAN Configuration Screen] — [Server Management Screen
]
1. IP Address
Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]
Help Text:
View/Edit IP Address. Press <Enter> to edit.
Comments: This specifies the IPv4 Address for the Baseboard LAN. There is a separate IPv4
Address field for the Intel
®
RMM4 LAN configuration.
When IPv4 addressing is used, the initial value for this field is acquired from the BMC. The setting of IP
Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).
When IPv6 addressing is enabled, this field is grayed out and inactive.
Back to [BMC LAN Configuration Screen] — [Server Management Screen
]
2. Subnet Mask
Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]
Help Text:
View/Edit Subnet Mask. Press <Enter> to edit.
Comments: This specifies the IPv4 addressing Subnet Mask for the Baseboard LAN. There is
a separate IPv4 Subnet Mask field for the Intel
®
RMM4 LAN configuration.
When IPv4 addressing is used, the initial value for this field is acquired from the BMC. The setting of IP
Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).
When IPv6 addressing is enabled, this field is grayed out and inactive.
Back to [BMC LAN Configuration Screen] — [Server Management Screen
]
3. Gateway IP
Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]
Help Text:
View/Edit Gateway IP. Press <Enter> to edit.
Comments: This specifies the IPv4 addressing Gateway IP for the Baseboard LAN. There is
a separate IPv4 Gateway IP field for the Intel
®
RMM4 LAN configuration.
When IPv4 addressing is used, the initial value for this field is acquired from the BMC. The setting of IP
Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).
When IPv6 addressing is enabled, this field is grayed out and inactive.
Back to [BMC LAN Configuration Screen] — [Server Management Screen
]