S2600GZ and S2600GL

Table Of Contents
Intel® Server Board S2600GZ/GL TPS Light Guided Diagnostics
associated Memory Slot Fault LED. These LEDs are only active when the system is in the ‘on’ state. The BMC
will not activate or change the state of the LEDs unless instructed by the BIOS.
10.8
CPU Fault LEDs
The server board includes a CPU fault LED for each CPU socket. The CPU Fault LED is lit if there is an MSID
mismatch error is detected (that is, CPU power rating is incompatible with the board).
10.9
System Power Good LED
The Power Good LED is illuminated when system power is turned on and DC power to the server board is
within acceptable limits.
10.10
CATERR LED
For processors that support the Intel
®
Quick Path Interconnect interface, the CATERR# signal is used to
indicate that a catastrophic error condition has been experienced by the processor. Should such an error
occur, the CATERR LED on the server board will illuminate.
Revision 2.4
99