The following diagram illustrates the fan speed control structure.
Figure 18. Fan Control Model
4.3 System Fans
Six managed dual rotor 40mm x 56mm system fans and an embedded fan for each installed power supply,
provide the primary airflow for the system. The following table provides the volumetric air flow requirements for
different 2U system configurations.
Table 21. 1U System Volumetric Air Flow Requirements
System Configuration
Air Flow Range (CFM)
All 1U system
1180 CFM
The system is designed for fan redundancy when configured with two power supply modules. Should a single
fan fail (system fan or power supply fan), platform management will adjust air flow of the remaining fans and
manage other platform features to maintain system thermals. Fan redundancy is lost if more than one fan is in
a failed state.