Intel Server Board S2400BB

Intel® Server Board S2400BB TPS
Revision 2.0
124
Error Code
Error Message
Response
85E4
DIMM_M1 encountered a Serial Presence Detection (SPD) failure
Major
85E5
DIMM_M2 encountered a Serial Presence Detection (SPD) failure
Major
85E6
DIMM_M3 encountered a Serial Presence Detection (SPD) failure
Major
85E7
DIMM_N1 encountered a Serial Presence Detection (SPD) failure
Major
85E8
DIMM_N2 encountered a Serial Presence Detection (SPD) failure
Major
85E9
DIMM_N3 encountered a Serial Presence Detection (SPD) failure
Major
85EA
DIMM_O1 encountered a Serial Presence Detection (SPD) failure
Major
85EB
DIMM_O2 encountered a Serial Presence Detection (SPD) failure
Major
85EC
DIMM_O3 encountered a Serial Presence Detection (SPD) failure
Major
85ED
DIMM_P1 encountered a Serial Presence Detection (SPD) failure
Major
85EE
DIMM_P2 encountered a Serial Presence Detection (SPD) failure
Major
85EF
DIMM_P3 encountered a Serial Presence Detection (SPD) failure
Major
8604
POST Reclaim of non-critical NVRAM variables
Minor
8605
BIOS Settings are corrupted
Major
8606
NVRAM variable space was corrupted and has been reinitialized
Major
92A3
Serial port component was not detected
Major
92A9
Serial port component encountered a resource conflict error
Major
A000
TPM device not detected.
Minor
A001
TPM device missing or not responding.
Minor
A002
TPM device failure.
Minor
A003
TPM device failed self test.
Minor
A100
BIOS ACM Error
Major
A421
PCI component encountered a SERR error
Fatal
A5A0
PCI Express component encountered a PERR error
Minor
A5A1
PCI Express component encountered an SERR error
Fatal
A6A0
DXE Boot Service driver: Not enough memory available to shadow a Legacy
Option ROM
Minor
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the BIOS uses
these beep codes to inform users on error conditions. The beep code is followed by a user-visible code
on the POST Progress LEDs
Table 61. POST Error Beep Codes
Beeps
Error Message
POST Progress Code
Description
1
USB device action
NA
Short beep sounded whenever a USB device is discovered
in POST, or inserted or removed during runtime
1 long
Intel
®
TXT security
violation
0xAE, 0xAF
System halted because Intel
®
Trusted Execution
Technology detected a potential violation of system
security.
3
Memory error
See Tables 28 and 29
System halted because a fatal error related to the memory
was detected.
2
BIOS Recovery
started
NA
Recovery boot has been initiated
4
BIOS Recovery
failure
NA
BIOS recovery has failed. This typically happens so quickly
after recovery us initiated that it sounds like a 2-4 beep
code.
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded
continuously. Codes that are common across all Intel server boards and systems that use same
generation chipset are listed in the following table. Each digit in the code is represented by a sequence
of beeps whose count is equal to the digit.