Intel Server Board S2400BB
Intel® Server Board S2400BB TPS
Revision 2.0
114
Table 55. Node Manager Health Event
Node Manager Health
Event
Request
Byte 1
- EvMRev
=04h (IPMI2.0 format)
Byte 2
– Sensor Type
=DCh (OEM)
Byte 3
– Sensor Number
(Node Manager Health sensor)
Byte 4
– Event Dir | Event Type
[0:6]
– Event Type
= 73h (OEM)
[7]
– Event Dir
=0 Asse
rtion Event
Byte 5
– Event Data 1
[0:3
] – Health Event Type
=0
2h – Sensor Node Manager
[4:5
]=10b – OEM code in byte 3
[6:7
]=10b – OEM code in byte 2
Byte 6
– Event Data 2
[0:3]
– Domain Id (Currently, supports only one domain,
Domain 0)
[4:7]
– Error type
=0
-9 - Reserved
=10
– Policy Misconfiguration
=11
– Power Sensor Reading Failure
=12
– Inlet Temperature Reading Failure
=13
– Host Communication error
=14
– Real-time clock synchronization failure
=
15 – Reserved
Byte 7
– Event Data 3
if error indication = 10 <PolicyId>
if error indication = 11 <PowerSensorAddress>
if error indication = 12 <InletSensorAddress>
Otherwise set to 0.