System Service Guide

Server System Features
Intel
®
Server System R1000JP Family Service Guide 9
Jumper Name Jumper Position Mode of Operation Note
2-3 Update
J2B5: BIOS Default
1-2 Normal Normal mode
2-3 Clear BIOS Settings BIOS settings are reset to factory default
Figure 9. Configuration Jumpers
Hard Disk Drive Carriers
The Intel
®
Server System R1000JP ships in two different basic SKUs, and with different maximum
number of hard disk drives, see below table for details:
Table 4. Hard Disk Drive Options
Intel
®
Server System Supported Hard Drive Type Maximum Hard Drive Number
R1304JP4TC/R1304JP4OC/R1304JP4GS 3.5-inch 4
R1208JP4TC/R1208JP4OC/R1208JP4GS 2.5-inch 8
Note: 1. Drives can consume up to 17 watts of power each. Drives must be specified to run at a maximum
ambient temperature of 45°C.
Bezel
The front bezel is available as optional accessory for the server system:
Figure 10. Front view of System Bezel
Hot-Swap SAS/SATA Backplane
The Hot-Swap SAS/SATA backplane serves as an interface between the mother board and the
system drives. The following diagrams show the location for each connector found on
the backplane.
4 x 3.5-inch Hard Drive Backplane
A
SAS/SATA Hot-swap Connectors
Figure 11. 4 x 3.5-inch Hard Drive Backplane Components (Front View)