Technical Product Specification
Power Sub-System IntelP
®
P Server System R1000JP Family TPS
The pass criteria include:
No unsafe operation is allowed under any condition
All power supply output voltage levels to stay within proper spec levels
No change in operating state or loss of data during and after the test profile
No component damage under any condition
The power supply shall comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003
using the IEC 61000-4-5: Edition 1.1:2001-04 test standard and performance criteria B defined
in Annex B of CISPR 24.
3.2.6.15 Power Recovery
The power supply must recover automatically after an AC power failure. AC power failure is
defined to be any loss of AC power that exceeds the dropout criteria.
3.2.6.16 Voltage Interruptions
The power supply must comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003
using the IEC 61000-4-11: Second Edition: 2004-03 test standard and performance criteria C
defined in Annex B of CISPR 24.
3.2.6.17 Power Factor
The power supply must meet the power factor requirements stated in the Energy Star
®
Program
Requirements for Computer Servers. These requirements are stated below.
Output power
20% load
50% load
100% load
Power factor
0.8
0.9
0.95
Tested at 230Vac, 50Hz and 60Hz, and 115VAC, 60Hz.
Tested according to Generalized Internal Power Supply Efficiency Testing Protocol Rev 6.4.3.
This is posted at
http://efficientpowersupplies.epri.com/methods.asp.
3.2.6.18 AC Input Voltage Specification
The power supply must operate within all specified limits over the following input voltage range.
Harmonic distortion of up to 10% of the rated line voltage must not cause the power supply to
go out of specified limits. Application of an input voltage below 85VAC shall not cause damage
to the power supply, including a blown fuse.
Table 27. AC Input Voltage Range
PARAMETER
MIN
RATED
VMAX
Start up VAC
Power Off
VAC
Voltage (110)
90 Vrms
100-127 Vrms
140 Vrms
85VAC +/-
4VAC
70VAC +/-
5VAC
Voltage (220)
180 Vrms
200-240 Vrms
264 Vrms
Frequency
47 Hz
50/60
63 Hz
Notes:
Maximum input current at low input voltage range shall be measured at 90VAC, at maximum load.
Maximum input current at high input voltage range shall be measured at 180VAC, at maximum load.
This requirement is not to be used for determining agency input current markings.
Revision 1.7
Intel
order number: G71652-008
30