Technical Product Specification
IntelP
®
P Server System R1000JP Family TPS Power Sub-System
0 to 1/2 AC
cycle
95%
Nominal AC Voltage ranges
50/60Hz
No loss of function or performance
> 1 AC cycle
>30
%
Nominal AC Voltage ranges
50/60Hz
Loss of function acceptable, self
recoverable
Table 25. AC Line Surge Transient Performance
AC Line Surge
Duration
Surge
Operating AC Voltage
Line Frequency
Performance Criteria
Continuous
10%
Nominal AC Voltages
50/60Hz
No loss of function or performance
0 to ½ AC
cycle
30%
Mid-point of nominal AC
Voltages
50/60Hz
No loss of function or performance
3.2.6.10 Susceptibility Requirements
The power supply shall meet the following electrical immunity requirements when connected to
a cage with an external EMI filter which meets the criteria defined in the SSI document EPS
Power Supply Specification. For further information on Intel
®
standards, please request a copy
of the Intel
®
Environmental Standards Handbook.
Table 26. Performance Criteria
Level
Description
A
The apparatus shall continue to operate as intended. No degradation of performance.
B
The apparatus shall continue to operate as intended. No degradation of performance
beyond spec limits.
C
Temporary loss of function is allowed provided the function is self-recoverable or can be
restored by the operation of the controls.
3.2.6.11 Electrostatic Discharge Susceptibility
The power supply shall comply with the limits defined in EN 55024: 1998/A1: 2001/A2: 2003
using the IEC 61000-4-2: Edition 1.2: 2001-04 test standard and performance criteria B defined
in Annex B of CISPR 24.
3.2.6.12 Fast Transient/Burst
The power supply shall comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003
using the IEC 61000-4-4: Second edition: 2004-07 test standard and performance criteria B
defined in Annex B of CISPR 24.
3.2.6.13 Radiated Immunity
The power supply shall comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003
using the IEC 61000-4-3: Edition 2.1: 2002-09 test standard and performance criteria A defined
in Annex B of CISPR 24.
3.2.6.14 Surge Immunity
The power supply shall be tested with the system for immunity to AC Unidirectional wave; 2kV
line to ground and 1kV line to line, per EN 55024: 1998/A1: 2001/A2: 2003, EN 61000-4-5:
Edition 1.1:2001-04 .
Revision 1.7 29