Technical Product Specification
Product Overview IntelP
®
P Server System R1000JP Family TPS
Parameter
Limits
Humidity
Shipping 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures
from 25°C to 35°C).
Shock
Operating Half sine, 2g, 11 mSec.
Unpackaged Trapezoidal, 25 g, velocity change is based on packaged weight.
Packaged Product Weight: ≥ 40 to < 80.
Non-palletized Free Fall Height = 18 inches.
Palletized (single product) Free Fall Height = NA.
Vibration
Unpackaged 5 Hz to 500 Hz 2.20 g RMS random.
Packaged 5 Hz to 500 Hz 1.09 g RMS random.
AC-DC
Voltage 90 V to 132 V and 180 V to 264 V.
Frequency 47 Hz to 63 Hz.
Source
Interrupt
No loss of data for power line drop-out of 12 mSec.
Surge Non-
operating and
operating
Unidirectional
Line to earth
Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged 12.0 kV
Contact
Discharge
8.0 kV
Acoustics
Sound
Power
Measured
Air Flow Operation 11 to 80 CFM
Power in
Watts
<300 W ≥300 W ≥600 W ≥1000 W
Servers/Rack
Mount BA
7.0 7.0 7.0 7.0
Note:
See the Intel
®
S1600JP Product Family Power Budget and Thermal Configuration Tool for system configuration
requirements and limitations.
Revision 1.7
Intel
order number: G71652-008