Technical Product Specification
Intel® Server Board S1600JP TPS Platform Management Functional Overview
o Signed Firmware (improved security)
o Inventory data/system information export (partial SMBIOS table)
Enhancements to fan speed control
DCMI 1.1 compliance
Support for embedded web server UI in basic manageability feature set
Enhancements to embedded web server
o Human-readable SEL
o Additional system configurability
o Additional system monitoring capability
o Enhanced on-line help
Enhancements to KVM redirection
o Support resolution up to 1600x1200
Management support for PMBus* rev1.2 compliant power supplies
BMC Data Repository (Managed Data Region Feature)
System Airflow Monitoring
Exit Air Temperature Monitoring
Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Memory Thermal Management
Power Supply Fan Sensors
Enable/Disable of System Reset Due CPU Errors
Energy Star Server Support
SmaRT/CLST
Power Supply Cold Redundancy
Power Supply FW Update
Power Supply Compatibility Check
BMC FW reliability enhancements:
o Redundant BMC boot blocks to avoid possibility of a corrupted boot block
resulting in a scenario that prevents a user from updating the BMC.
o BMC System Management Health Monitoring
4.2
Advanced Configuration and Power Interface (ACPI)
The server board has support for the following ACPI states:
Table 13. ACPI Power States
State
Supported
Description
S0
Yes
Working.
The front panel power LED is on (not controlled by the BMC).
The fans spin at the normal speed, as determined by sensor inputs.
Front panel buttons work normally.
38 Revision 1.9