Technical Product Specification

Intel® Server Board S1600JP TPS Platform Management Functional Overview
BMC self-test: The BMC performs initialization and run-time self-tests and makes
results available to external entities.
See also the Intelligent Platform Management Interface Specification Second Generation v2.0.
4.1.2
Non-IPMI Features
The BMC supports the following non-IPMI features. This list does not preclude support for future
enhancements or additions.
In-circuit BMC firmware update
BMC FW reliability enhancements:
o Redundant BMC boot blocks to avoid possibility of a corrupted boot block
resulting in a scenario that prevents a user from updating the BMC.
o BMC System Management Health Monitoring
o Signed firmware images for increased security
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality
Enable/Disable of System Reset Due CPU Errors
Chassis intrusion detection
Fan speed control
Fan redundancy monitoring and support
Hot-swap fan support
Power Supply Fan Sensors
System Airflow Monitoring
Exit Air Temperature Monitoring
Acoustic management: Support for multiple fan profiles
Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Platform environment control interface (PECI) thermal management support
Memory Thermal Management
DIMM temperature monitoring: New sensors and improved acoustic management
using closed-loop fan control algorithm taking into account DIMM temperature
readings.
Power supply redundancy monitoring and support
Power unit management: Support for power unit sensor. The BMC handles power-
good dropout conditions.
Intel
®
Intelligent Power Node Manager support
Signal testing support: The BMC provides test commands for setting and getting
platform signal states.
The BMC generates diagnostic beep codes for fault conditions
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID
LED. It supports secure lockout of certain front panel functionality and monitors
button presses. The chassis ID LED is turned on using a front panel button or
a command.
Power state retention
36 Revision 1.9