Technical Product Specification
Appendix C: BIOS Sensors and SEL Data IntelĀ® Server Board S1600JP TPS
Sensor Name
Sensor
Number
Sensor
Owner
(GID)
Sensor Type
Event/Reading Type
Offset Values
Event Data 2
Event Data 3
Memory RAS
Configuration
Status
02h
01h (BIOS
POST)
0Ch
(Memory)
09h (Digital Discrete)
0h = RAS Configuration
Disabled
1h = RAS Configuration
Enabled
ED2 =
[7:4] =
Reserved
[3:0] Config
Err
0 = None
3 = Invalid
DIMM Config
for RAS Mode
ED3 =
[7:4] = Reserved
[3:0] = RAS Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank Sparing
Memory ECC
Error
02h
33h (SMI
Handler)
0Ch
(Memory)
6Fh (Sensor Specific
Offset)
0h = Correctable Error
1h = Uncorrectable
Error
ED2 =
[7:2] =
Reserved
[1:0] = Rank
on DIMM
0-3 = Rank
Number
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel A-
D for Socket
[2:0] = DIMM
0-2 = DIMM 1-3
on Channel
Legacy PCI Error
03h
33h (SMI
Handler)
13h (Critical
Interrupt)
6Fh (Sensor Specific
Offset)
4h = PCI PERR
5h = PCI SERR
ED2 =
[7:0] = Bus
Number
ED3 =
[7:3] = Device
Number
[2:0] = Function
Number
210 Revision 1.9