Technical Product Specification
Intel® Server Board S1600JP TPS Appendix B: Integration BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 3
DIMM
Aggregate
Thermal Margin
1
(P3 DIMM
Thrm Mrgn1)
B4h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Processor 3
DIMM
Aggregate
Thermal Margin
2
(P3 DIMM
Thrm Mrgn2)
B5h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Processor 4
DIMM
Aggregate
Thermal Margin
1
(P4 DIMM
Thrm Mrgn1)
B6h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Processor 4
DIMM
Aggregate
Thermal Margin
2
(P4 DIMM
Thrm Mrgn2)
B7h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Fan
Tachometer
Sensors
(Chassis
specific
sensor names)
BAh–
BFh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
2
As and
De
Analog R, T M -
Revision 1.9 201