Technical Product Specification

Intel® Server Board S1600JP TPS Appendix B: Integration BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 3
Status
(P3 Status)
72h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M X
07 - Presence OK
Processor 4
Status
(P4 Status)
73h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M X
07 - Presence OK
Processor 1
Thermal Margin
(P1 Therm
Margin)
74h All
Temperat
ure
01h
Threshold
01h
- - - Analog R, T A
Processor 2
Thermal Margin
(P2 Therm
Margin)
75h All
Temperat
ure
01h
Threshold
01h
- - - Analog R, T A
Processor 3
Thermal Margin
(P3 Therm
Margin)
76h
Platform-
specific
Temperat
ure
01h
Threshold
01h
- - - Analog R, T A
Processor 4
Thermal Margin
(P4 Therm
Margin)
77h
Platform-
specific
Temperat
ure
01h
Threshold
01h
- - - Analog R, T A
Processor 1
Thermal
Control %
(P1 Therm
Ctrl %)
78h All
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 2
Thermal
Control %
(P2 Therm
Ctrl %)
79h All
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A