Technical Product Specification

Intel® Server Board S1600JP TPS Appendix B: Integration BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Redundancy)
03 - Non-redundant: Sufficient
resources. Transition from
redundant
Degraded
04 - Non-redundant: Sufficient
resources. Transition from
insufficient.
Degraded
05 - Non-redundant: insufficient
resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant degraded from
non-redundant
Degraded
SSB Thermal
Trip
(SSB Therm
Trip)
0Dh All
Temperat
ure
01h
Digital
Discrete
03h
01 State Asserted Fatal
As and
De
Trig
Offset
M X
IO Module
Presence
(IO Mod
Presence)
0Eh
Platform-
specific
Module/Bo
ard
15h
Digital
Discrete
08h
01 Inserted/Present OK
As and
De
Trig
Offset
M -
SAS Module
Presence
(SAS Mod
Presence)
0Fh
Platform-
specific
Module/Bo
ard
15h
Digital
Discrete
08h
01 Inserted/Present OK
As and
De
Trig
Offset
M X
BMC Firmware
Health
(BMC FW
Health)
10h All
Mgmt
Health
28h
Sensor
Specific
6Fh
04 Sensor Failure Degraded As -
Trig
Offset
A X
System Airflow
(System
Airflow)
11h All
Other
Units
0Bh
Threshold
01h
Analog
Revision 1.9 189