Technical Product Specification

Intel® Server Board S1600JP TPS Appendix B: Integration BMC Sensor Tables
Note: All sensors listed as follows may not be present on all platforms. Please check platform EPS section for platform applicability and platform chassis section
for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or
power supply).
Table 97. BMC Core Sensors
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Unit
Status
(Pwr Unit
Status)
01h All
Power
Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As and
De
Trig
Offset
A X
02 - 240 VA power down
Fatal
04 - A/C lost
OK
05 - Soft power control failure
Fatal
06 - Power unit failure
Power Unit
Redundancy
Not
e1
(Pwr Unit
Redund)
02h
Chassis-
specific
Power
Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As
Trig
Offset
M X
01 - Redundancy lost
Degraded
02 - Redundancy degraded
Degraded
03 - Non-redundant: sufficient
resources. Transition from
full redundant state.
Degraded
04 Non-redundant: sufficient
resources. Transition from
insufficient state.
Degraded
05 - Non-redundant: insufficient
resources
Fatal
06 Redundant: degraded
from fully redundant state.
Degraded
07 Redundant: Transition
from non-redundant state.
Degraded
IPMI Watchdog
(IPMI
Watchdog)
03h All
Watchdog
2
23h
Sensor
Specific
6Fh
00 - Timer expired, status only
OK As
Trig
Offset
A X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical
04h
Chassis Physical Sensor
00 - Chassis intrusion
Degraded
As and
Trig
A
X
Revision 1.9 187