Technical Product Specification

Appendix B: Integration BMC Sensor Tables Intel® Server Board S1600JP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 3
VRD
Temperature
(P3 VRD Hot)
92h All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As and
De
Trig
Offset
A
Processor 4
VRD
Temperature
(P4 VRD Hot)
93h All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As and
De
Trig
Offset
A
Processor 1
Memory VRD
Hot 0-1
(P1 Mem01
VRD Hot)
94h All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As and
De
Trig
Offset
A
Processor 1
Memory VRD
Hot 2-3
(P1 Mem23
VRD Hot)
95h All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As and
De
Trig
Offset
A
Processor 2
Memory VRD
Hot 0-1
(P2 Mem01
VRD Hot)
96h All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As and
De
Trig
Offset
A
Processor 2
Memory VRD
Hot 2-3
(P2 Mem23
VRD Hot)
97h All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit exceeded Non-fatal
As and
De
Trig
Offset
A
198 Revision 1.9