Technical Product Specification
Intel® Server Board S1600JP TPS Appendix B: Integration BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Network
Interface
Controller
Temperature
(LAN NIC
Temp)
2Fh All
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Fan
Tachometer
Sensors
(Chassis
specific
sensor names)
30h–
3Fh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
Note3
As and
De
Analog R, T M -
Fan Present
Sensors
(Fan x Present)
40h–
4Fh
Chassis
and
Platform
Specific
Fan
04h
Generic
08h
01 - Device inserted OK
As and
De
-
Trigge
red
Offset
Auto
-
Power Supply 1
Status
Note2
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
–
Trig
Offset
A X
01 - Failure
Degraded
02 – Predictive Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration error
OK
Power Supply 2
Status
Note2
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
–
Trig
Offset
A X
01 - Failure
Degraded
02 – Predictive Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other
Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other
Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Revision 1.9 193