Technical Product Specification
Connector/Header Locations and Pin-out IntelĀ® Server Board S1600JP TPS
7.4
Fan Headers
The server board provides six 8 pin fan headers (J1K1, J1K2, J3K1, J4K2, J6K2, and J6K3).
The following table defined the pin-out.
Table 81. Baseboard Fan Connector Pin-Out (J1K1, J1K2, J3K1, J4K2, J6K2, and J6K3)
Pin
Signal Name
1
GND
2
12V
3
Tachx
4
PWMy
5 GND
6 12V
7
Tachz
8
PWMy
7.5
Fan Domain Mapping
S1600JP has six system fan connector can connector 12 fans. Those system fan connectors
belongs to four fan domains. S1600JP BMC FW can control the fan speed by the fan domain.
Table 82. S1600JP Fan Connctor and Fan Domain Mapping Table
Connector
Layout
Description
Ref.
Description
#
Pins
Fan
Domain
Tach
Meter
Sensor
Number
_SDR_Tag
Expected
Max RPM
System Fan
1A
SYS
FAN_1
J1K1(A) 8
2 8 30 OTHER_FAN_1A 25000
System Fan
1B
2 9 31 OTHER_FAN_1B 25000
System Fan
2A
SYS
FAN_2
J1K2(A) 8
2 6 32 OTHER_FAN_2A 25000
System Fan
2B
2 7 33 OTHER_FAN_2B 25000
System Fan
3A
SYS
FAN_3
J3K1(A) 8
0 4 34 OTHER_FAN_3A 25000
System Fan
3B
0 5 35 OTHER_FAN_3B 25000
System Fan
4A
SYS
FAN_4
J4K2(A) 8
0 2 36 OTHER_FAN_4A 25000
System Fan
4B
0 3 37 OTHER_FAN_4B 25000
System Fan
5A
SYS
FAN_5
J6K2(A) 8
1 0 38 OTHER_FAN_5A 25000
System Fan
5B
1 1 39 OTHER_FAN_5B 25000
System Fan
6A
SYS
FAN_6
J6K3(A) 8
3 10 3A OTHER_FAN_6A 25000
System Fan
6B
3 11 3B OTHER_FAN_6B 25000
170 Revision 1.9