Technical Product Specification

Connector/Header Locations and Pin-out Intel® Server Board S1600JP TPS
Table 60. System Status LED
Color
State
System Status
Description
Green
Solid on
Ok
System ready
Green
~1 Hz blink
Degraded
BIOS detected
Unable to use all of the installed memory (more than one
DIMM installed).
1
In a mirrored configuration, when memory mirroring takes
place and system loses memory redundancy. This is not
covered by (2).
1
PCI Express* correctable link errors.
Integrated BMC detected
Redundancy loss such as a power supply or fan.
Applies
only if the associated platform subsystem has redundancy
capabilities.
CPU disabled if there are two CPUs and one CPU is
disabled.
Fan alarm Fan failure. Number of operational fans should
be more than minimum number needed to cool the system.
Non-critical threshold crossed Temperature, voltage,
power nozzle, power gauge, and PROCHOT2 (Therm Ctrl)
sensors.
Battery failure.
Predictive failure when the system has redundant power
supplies.
Amber
~1 Hz blink
Non-Fatal
Non-fatal alarm system is likely to fail:
BIOS Detected
In non-mirroring mode, if the threshold of ten correctable
errors is crossed within the window.
1
PCI Express* uncorrectable link errors.
Integrated BMC Detected
Critical threshold crossed Voltage, temperature, power
nozzle, power gauge, and PROCHOT (therm Ctrl) sensors.
VRD Hot asserted.
Minimum number of fans to cool the system are not present
or have failed.
Amber Solid on Fatal Fatal alarm system has failed or shutdown:
BIOS Detected
DIMM failure when there is one DIMM present and no good
memory is present.
1
Run-time memory uncorrectable error in non-redundant
mode.
1
CPU configuration error (for instance, processor stepping
mismatch).
Integrated BMC Detected
CPU CATERR signal asserted.
CPU 1 is missing.
CPU THERMTRIP.
No power good power fault.
Power Unit Redundancy sensor Insufficient resources
offset (indicates not enough power supplies are present).
Off
N/A
Not ready
Main power off
Notes:
1. The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to
provide the contribution to the system status LED.
2. Support for an upper, non-critical threshold limit is not provided in default SDR configuration. However if a
user does enable this threshold in the SDR, then the system status LED should behave as described.
158 Revision 1.9