Technical Product Specification
BIOS Setup Interface Intel® Server Board S1600JP TPS
Setup Item
Options
Help Text
Comments
Resume on AC
Power Loss
Stay Off
Last state
Power on
System action to take on AC power
loss recovery.
[Stay Off] - System stays off.
[Last State] - System returns to the
same state before the AC power
loss.
[Power On] - System powers on.
This option controls the policy that
the BMC will follow when AC power
is restored after an unexpected
power outage. The BMC will either
hold DC power off or always turn it
on to boot the system, depending on
this setting – and in the case of Last
State, depending on whether the
power was on and the system was
running before the AC power went
off.
When this setting is changed in
Setup, the new setting will be sent
to the BMC. However, the BMC
maintains (“owns”) this Power
Restore Policy setting, and it can be
changed independently with an IPMI
command to the BMC. BIOS gets
this setting from the BMC early in
POST, and also for the Setup
Server Management screen.
Note: System will automatically
power on after when AC is applied
doing a CMOS clear because this
option will not take effect at this
situation.
120 Revision 1.9