Intel Server System R2000BB Family

Intel
®
Server System R2000BB Product Family TPS
Revision
2.0
5
2.2 System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 2. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating ASHRAE Class A2 Continuous Operation. 10º C to 35º C (50º F to 95º F) with the maximum
rate of change not to exceed 10°C per hour
ASHRAE Class A3 Includes operation up to 40C for up to 900 hrs per year.
ASHRAE Class A4 Includes operation up to 45C for up to 90 hrs per year.
Shipping -40º C to 70º C (-40º F to 158º F)
Altitude
Operating Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping 50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures from 25° C
to 35° C)
Shock
Operating Half sine, 2g, 11 mSec
Unpackaged Trapezoidal, 25 g, velocity change is based on packaged weight
Packaged Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged 5 Hz to 500 Hz 2.20 g RMS random
Packaged 5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage 90 Hz to 132 V and 180 V to 264 V
Frequency 47 Hz to 63 Hz
Source Interrupt No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
Unidirectional
Line to earth Only AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged 12.0 kV
Contact
Discharge
8.0 kV
Air Flow
Operation R2312BB4 16-103 CFM
R2308BB4 25-152 CFM
R2224BB4 20-126 CFM
R2216BB4 27-152 CFM
Acoustics
Sound Power
Measured
Power in Watts <300 W ≥300 W ≥600 W ≥1000 W
Servers/Rack
Mount BA
7.0 7.0 7.0 7.0