Intel Server Board S2400BB

Intel® Server Board S2400BB TPS
Revision 2.0
58
Parameter 21 (VLAN Priority) of the Set LAN Config Parameters IPMI command is now implemented and a
range from 0-7 will be allowed for VLAN Priorities. Please note that bits 3 and 4 of Parameter 21 are
considered Reserved bits.
Parameter 25 (VLAN Destination Address) of the Set LAN Config Parameters IPMI command is not supported
and returns a completion code of 0x80 (parameter not supported) for any read/write of parameter 25.
If the BMC IP address source is DHCP, then the following behavior is seen:
If the BMC is first configured for DHCP (prior to enabling VLAN), when VLAN is enabled, the BMC
performs a discovery on the new VLAN in order to obtain a new BMC IP address.
If the BMC is configured for DHCP (before disabling VLAN), when VLAN is disabled, the BMC performs a
discovery on the LAN in order to obtain a new BMC IP address.
If the BMC IP address source is Static, then the following behavior is seen:
If the BMC is first configured for static (prior to enabling VLAN), when VLAN is enabled, the BMC has the
same IP address that was configured before. It is left to the management application to configure a
different IP address if that is not suitable for VLAN.
If the BMC is configure for static (prior to disabling VLAN), when VLAN is disabled, the BMC has the
same IP address that was configured before. It is left to the management application to configure a
different IP address if that is not suitable for LAN.
6.10.7 Secure Shell (SSH)
Secure Shell (SSH) connections are supported for SMASH-CLP sessions to the BMC.
6.10.8 Serial-over-LAN (SOL 2.0)
The BMC supports IPMI 2.0 SOL.
IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard payload type (01h)
over RMCP+.
Three commands are implemented for SOL 2.0 configuration.
“Get SOL 2.0 Configuration Parameters” and “Set SOL 2.0 Configuration Parameters”: These commands
are used to get and set the values of the SOL configuration parameters. The parameters are
implemented on a per-channel basis. For details, see Error! Reference source not found..
“Activating SOL”: This command is not accepted by the BMC. It is sent by the BMC when SOL is
activated to notify a remote client of the switch to SOL.
Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used, it should be
negotiated when the IPMI-over LAN session is established.