Intel Server Board S2400BB
Intel® Server Board S2400BB TPS
Revision 2.0
111
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert
/ De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Baseboard +1.35V P2 Low
Voltage Memory CD VDDQ
(BB +1.35 P2LV CD)
E7h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A –
Baseboard +3.3V Riser 1
Power Good
(BB +3.3 RSR1 PGD)
EAh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A –
Baseboard +3.3V Riser 2
Power Good
(BB +3.3 RSR2 PGD)
EBh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A –
Hard Disk Drive 1 -15 Status
(HDD 1 - 15 Status)
F0h
-
FEh
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 - Drive Presence
OK
As
and
De
– Trig Offset A X
01- Drive Fault
Degraded
07 - Rebuild/Remap in
progress
Degraded