Intel Server Board S2400BB

Intel® Server Board S2400BB TPS
Revision 2.0
103
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert
/ De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Voltage Regulator Watchdog
(VR Watchdog)
0Bh All
Voltage
02h
Digital
Discrete
03h
01 State Asserted Fatal
As
and
De
Trig Offset M X
Fan Redundancy
Note1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As
and
De
Trig Offset A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperature
01h
Digital
Discrete
03h
01 State Asserted Fatal
As
and
De
Trig Offset M X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 Inserted/Present OK
As
and
De
Trig Offset M X
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 Inserted/Present OK
As
and
De
Trig Offset M X
BMC Firmware Health
(BMC FW Health)
10h All
Mgmt Health
28h
Sensor
Specific
6Fh
04 Sensor Failure
Degraded