Specification Update

Monthly Specification Update October, 2014
7
Status The issue may be fixed in future BIOS.
Workaround NA.
12. The power supply without C6/C7 function may not work with Intel
®
Server Board S1200V3RP
Problem The power supply without C6/C7 function may not work with Intel
®
Server
Board S1200V3RP. By default C6/C7 is disabled in BIOS setting. But if the
user enables C6/C7, the power supply that doesnt have C6/C7 cannot be
supported.
Implication The platform doesnt support the power supply that doesnt have C6/C7
function.
Status Will not fix.
Workaround The user needs to make sure C6/C7 is disabled in BIOS setting to use the
power supply that doesnt have C6/C7 function.
13. The USB device cannot be removed when installing Windows* operating
system
Problem During Windows* operating system installation, the USB device cannot be
removed until the installation is done if any USB device is plugged in.
Implication The user needs to keep the USB device in the system when installing
Windows* operating system.
Status Will not fix.
Workaround NA.
14. There will be an error of Processor 1 P1 MTT after installing VMware*
ESXi 5.1 on the Intel
®
Server Board S1200V3RP
Problem After installing VMware* ESXi 5.1 on the Intel
®
Server Board S1200V3RP and
going to the vSphere interface to check Motherboard sensors, there will be an
“alert” of Processor 1 P1 MTT (Memory Thermal Throttling) – upper fatal error.
Implication It is a fake alert with no functional impact.
Status The issue is fixed in BIOS R01.04.0002
Workaround NA.