Monthly Specification Update Intel®Server Board S1200V3RPL Intel®Server Board S1200V3RPS Intel®Server Board S1200V3RPO Intel®Server Board S1200V3RPM Intel®Server System R1304RPSSFBN Intel®Server System R1304RPOSHBN Intel®Server System R1208RPOSHOR Intel®Server System R1208RPMSHOR Intel®Server System R1304RPMSHOR Intel®Server System P4308RPLSHDR Intel Order Number H12643-001 October, 2014
October, 2014 Monthly Specification Update Revision History Date Modifications June, 2013 Initial release. July, 2013 No update. August, 2013 No update. September, 2013 Updated Errata 14 and 15. October, 2013 No update. November, 2013 No update. December, 2013 No update. January, 2014 Updated Errata 16 and 17. February, 2014 Updated Errata 18. March, 2014 Updated Errata 19.
Monthly Specification Update October, 2014 Disclaimers The Intel products specified may contain design defects or errors known as errata that may cause the product to deviate from the published specifications. Current characterized errata are documented in this Specification Update. Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
October, 2014 Monthly Specification Update Contents Preface ....................................................................................................................................... 1 Summary Tables of Changes ................................................................................................... 2 Errata ......................................................................................................................................... 4 1.
Monthly Specification Update October, 2014 22. No video output from the onboard VGA when installing Redhat6U5 if Integrated Graphic is enabled in the BIOS .............................................................................................. 10 23. It takes a long time to log in Windows and results in very high CPU utilization when more than 16G Memory is populated ..................................................................................... 10 24.
October, 2014 Monthly Specification Update This page intentionally left blank vi
Monthly Specification Update October, 2014 Preface This document communicates product Errata and Documentation Changes and Corrections for the following Intel Server Products: Intel® Server Board S1200V3RPL/S1200V3RPS/S1200V3RPO/S1200V3RPM Intel® Server System R1304RPSSFBN/R1304RPOSHBN/R1208RPOSHOR/ R1208RPMSHOR/R1304RPMSHOR Intel® Server System P4308RPLSHDN The items communicated in this document are defined as follows: Documentation Changes include typos, errors, or omissions from the current pu
October, 2014 Monthly Specification Update Summary Tables of Changes The following tables provide an overview of known errata and known document changes that apply to the specified Intel Server Products. The tables use the following notations: Doc Intel intends to update the appropriate documentation in a future revision. Fix Intel intends to correct this erratum. Fixed This erratum has been corrected. No Fix There are no plans to correct this erratum.
Monthly Specification Update October, 2014 No. Plans Description of Errata 21. Fixed The Integrated Graphic device may be shown as a yellow band in Windows 2012* when a PCIe addon Video card is installed on the Intel® Server Board S1200V3RP. 22. Fixed No video output from the onboard VGA when installing Redhat6U5 if Integrated Graphic is enabled in the BIOS. 23. Fixed It takes a long time to log in Windows and results in very high CPU utilization when more than 16G Memory is populated. 24.
October, 2014 Monthly Specification Update Errata 1. Linux* Operating Systems are not supported on RSTe mode Problem The Linux* Operating Systems including Redhat* Linux and Suse* Linux cannot be installed successfully on RSTe mode. Implication The RSTe mode cannot work on Linux* OS. Status This issue may be fixed in future driver or BIOS release. Workaround No. 2. VMWare* ESXi 5.1.
Monthly Specification Update 4. October, 2014 Redhat* Enterprise Linux 6 Update4 with KVM x64 uEFI ESRTII RAID 5 installation fails Problem The Redhat* Enterprise Linux 6 Update4 with KVM x64 uEFI version cannot be installded successfully on ESRTII RAID 5 mode. Implication The user may not use Redhat* Enterprise Linux 6 Update4 with KVM x64 uEFI version on ESRTII RAID 5 mode. Status The issue is under investigation. Workaround No. 5.
October, 2014 8. Monthly Specification Update On some motherboards, SEL log is not cleared from the manufactory Problem The user may get the board with SEL log not cleared. The SEL content is “Event Logging Disabled, System Event Log (#0x7) Informational event: System Event Log reports the log area has been cleared. BMC – LUN#0 (Channel#0)” and “Physical Security (Chassis IntruPhysical Scrty, Physical Scrty (#0x4) Informational event: Physical Scrty reports LAN Leash has been regained.
Monthly Specification Update Status The issue may be fixed in future BIOS. Workaround NA. 12. October, 2014 The power supply without C6/C7 function may not work with Intel® Server Board S1200V3RP Problem The power supply without C6/C7 function may not work with Intel® Server Board S1200V3RP. By default C6/C7 is disabled in BIOS setting. But if the user enables C6/C7, the power supply that doesn’t have C6/C7 cannot be supported.
October, 2014 15. Monthly Specification Update After installing Windows 2008* R2 SP1 on the Intel®Server Board S1200V3RP, the VM cannot be started when a RemoteFX* 3D virtual graphic card is installed in the VM of Hyper-V Problem After installing Windows 2008* R2 SP1 on the Intel® Server Board S1200V3RP, the VM cannot be started when a RemoteFX* 3D virtual graphic card is installed in the VM of Hyper-V. If VHD (RmoteFX) is disabled, the Hyper-V VM can start normally.
Monthly Specification Update Workaround Intel recommends that customers NOT install the PCIe storage devices in PCIe slot 4. If possible, move the adapter to slot 5, 6, or 7: 1. 2. 18. October, 2014 For the Intel® Server Board S1200V3RPL, use the modular Intel® RAID solutions listed in the supported product list to replace the storage adapters in PCIe slot 4. Options include the Intel® Integrated RAID Module RMS25CB and RMS25JB Families.
October, 2014 Workaround 21. Monthly Specification Update NA The Integrated Graphic device may be shown as a yellow band in Windows 2012* when a PCIe add-on Video card is installed on the Intel® Server Board S1200V3RP Problem The Integrated Graphic device may be shown as a yellow band in Windows 2012* when a PCIe add-on Video card is installed on the Intel® Server Board S1200V3RP. Implication The Integrated Video device may be shown as a yellow band in device manager.
Monthly Specification Update October, 2014 Implication It shows a black screen when using a VNC to connect to the S1200V3RPM board. Status Will not fix. Workaround Use the Microsoft Remote Desktop instead of a VNC. 25. It shows a black screen when enabling ESRTII and Integrated Graphic on the S1200V3RPM board Problem It shows a black screen when enabling ESRTII and Integrated Graphic on the S1200V3RPM board. Implication Users cannot enter the ESRTII configuration page.
October, 2014 28. Monthly Specification Update There is a TPM error shown in the event log after turning on Bitlocker in Windows 2012* R2 on the S1200V3RP series system Problem There is a TPM error shown in the event log after turning on Bitlocker in Windows 2012* R2 on the S1200V3RP series system. Implication Users can see an error log in Windows event log. Status Will not fix. Workaround Refer to Microsoft Knowledge Base for more details at http://support.microsoft.