Service Guide

Server Utilities
Intel
®
Server System R1000RP Service Guide 83
Back to [Memory Configuration Screen] [Advanced Screen] [Screen Map]
6. DIMM_A1
7. DIMM_A2
8. DIMM_B1
9. DIMM_B2
Help Text: <None>
Comments: Information only. Displays the status of each DIMM socket present on
the board. There is one line for each DIMM socket present on the board.
For each DIMM socket, the DIMM Status reflects one of the following three possible states:
Installed&Operational There is a DDR3 DIMM installed and operational in this slot.
Not Installed There is no DDR3 DIMM installed in this slot.
Failed/Disabled The DIMM installed in this slot has failed during initialization and/or
was disabled during initialization.
For each DIMM that is in the Installed & Operational state, the DIMM Size in GB of that
DIMM is displayed. This is the physical size of the DIMM, regardless of how it is counted in
the Effective Memory size.
Note: In “DIMM_XY”, X denotes the Channel Identifier A - P, and Y denotes the DIMM Slot
identifier 1 - 3 within the Channel. DIMM_A2 is the DIMM socket on Channel A, Slot 2. Not all
boards have the same number of channels and slots this is dependent on the board features.
S1200RP boards can have DIMMs A1, A2 to B1, B2
Back to [Memory Configuration Screen] [Advanced Screen] [Screen Map]
Mass Storage Controller Configuration
The Mass Storage Configuration screen allows the user to configure the Mass Storage controllers
that are integrated into the server board on which the BIOS is executing. This includes only
onboard Mass Storage controllers. Mass Storage controllers on add-in cards are not included in this
screen, nor are other storage mechanisms such as USB-attached storage devices or Network
Attached Storage.
There is one types of onboard controller configured in this screen, the AHCI SATA controller with
SATA drive support and RAID support. There are also informational displays of AHCI controller
configuration, and SATA Drive Information when applicable. If the presence of an Intel
®
Storage
Module is detected, the type of Storage Module is displayed as information-only.
To access this screen from the Main screen, select Advanced > Mass Storage Controller
Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen,
then select the desired screen.