Technical Product Specification
Product Overview Intel
®
Server System R1000RP Family TPS
Intel
order number: G91532-003 Revision 1.3
6
Parameter
Limits
Operating
Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures
from 25°C to 35°C).
Shock
Operating
Half sine, 2g, 11 mSec.
Unpackaged
Trapezoidal, 25g, velocity change is based on packaged weight.
Packaged
Product Weight: ≥ 40 to < 80.
Non-palletized Free Fall Height = 18 inches.
Palletized (single product) Free Fall Height = NA.
Vibration
Unpackaged
5 Hz to 500 Hz 2.20 g RMS random.
Packaged
5 Hz to 500 Hz 1.09 g RMS random.
AC-DC
Voltage
90 V to 132 V and 180 V to 264 V.
Frequency
47 Hz to 63 Hz.
Source
Interrupt
No loss of data for power line drop-out of 12 mSec.
Surge Non-
operating and
operating
Unidirectional
Line to earth
Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged
12.0 kV
Contact
Discharge
8.0 kV
Acoustics
Sound
Power
Measured
Power in
Watts
<300 W ≥300 W ≥600 W ≥1000 W
Servers/Rack
Mount BA
7.0 7.0 7.0 7.0
Note:
See the Intel
®
S1200V3RP Product Family Power Budget and Thermal Configuration Tool for system configuration
requirements and limitations.
Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock
requirement mentioned above through its own chassis development and system configuration. It
is the responsibility of the system integrator to determine the proper shock level of the board
and system if the system integrator chooses different system configuration or different chassis.
Intel Corporation cannot be held responsible, if components fail or the server board does not
operate correctly when used outside any of its published operating or non-operating limits.