Intel®Server System R1000RP Family Technical Product Specification Intel order number: G91532-003 Revision 1.
® Revision History Intel Server System R1000RP Family TPS Revision History Date Revision Number Modifications April 2013 1.0 Initial release. May 2013 1.1 Added a new system Intel Server System R1304RPMSHOR. May 2013 1.2 Removed the system Intel Server System R1304RPOSHOR. February 2014 1.3 Corrected the name of Intel RAID Activation Key as RKSATA4R5. ii ® ® ® Intel order number: G91532-003 Revision 1.
® Intel Server System R1000RP Family TPS Disclaimers Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT.
Table of Contents ® Intel Server System R1000RP Family TPS Table of Contents 1. Introduction ........................................................................................................................ 1 1.1 Chapter Outline ...................................................................................................... 1 1.2 Server Board Use Disclaimer ................................................................................. 1 2. Product Overview ................................
® Intel Server System R1000RP Family TPS Table of Contents 4.2.6 Thermal Sensor Input for Fan Speed Control ....................................................... 30 4.3 System Fans ........................................................................................................ 32 4.4 FRUSDR Utility .................................................................................................... 34 5 System Storage and Peripheral Options........................................................
List of Figures ® Intel Server System R1000RP Family TPS List of Figures Figure 1. Product Drawing .......................................................................................................... 2 Figure 2. System Photo............................................................................................................... 4 Figure 3. Chassis Dimension ...................................................................................................... 5 Figure 4.
® Intel Server System R1000RP Family TPS List of Figures Figure 40. LCP Main Menu ....................................................................................................... 47 Figure 41. LCP Event Menu ...................................................................................................... 48 Figure 42. LCP View Menu ....................................................................................................... 48 Figure 43. System Firmware Versions Menu ...............
List of Tables ® Intel Server System R1000RP Family TPS List of Tables Table 1. System Feature Set....................................................................................................... 2 Table 2. System SKU Matrix ....................................................................................................... 4 Table 3. System Environmental Limits Summary ........................................................................ 5 Table 4. Output Load for Efficiency Test ...........
® Intel Server System R1000RP Family TPS Revision 1.
® Intel Server System R1000RP Family TPS 1. Introduction Introduction This Technical Product Specification (TPS) provides system specific information detailing the features, functionality, and high-level architecture of the Intel® Server System R1000RP family. You can also reference the Intel® Server Board S1200V3RP Family Technical Product Specification to obtain greater detail of functionality and architecture of the server board integrated in this server system.
® Product Overview 2. Intel Server System R1000RP Family TPS Product Overview This generation of Intel® 1U server platforms offers a variety of system options to meet the entry level computing. The Intel® Server System R1000RP product family is comprised of several available 1U rack mount server systems that are all integrated with an Intel® Server Board S1200V3RPS, S1200V3RPO, or S1200V3RPM. This chapter provides a high-level overview of the system features.
® Intel Server System R1000RP Family TPS Feature System Connectors /Headers Product Overview Description External I/O connectors: DB9 serial port A connection. One DB-15 video connector. ® Two RJ-45 NIC connectors for 10/100/1000 Mb connections through the two Intel Ethernet Controller I210. Two USB 3.0 ports at the back of the board. Two USB 2.0 ports at the back of the board. Internal connectors/headers: One 2x10 pin USB 3.
® Product Overview Intel Server System R1000RP Family TPS Feature Server Management Description Integrated Baseboard Management Controller, IPMI 2.0 compliant. ® Support for Intel Remote Management Module 4 solutions (Optional except on S1200V3RPS). ® Support for Intel Remote Management Module 4 Lite solutions (Optional except on S1200V3RPS). ® Support for Intel System Management Software. ® Support for Intel Intelligent Power Node Manager (Need PMBus*-compliant power supply).
® Intel Server System R1000RP Family TPS 2.2 Product Overview System Dimensions Figure 3. Chassis Dimension 2.3 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 3. System Environmental Limits Summary Parameter Limits Temperature Operating ASHRAE Class A2 – Continuous Operation. 10ºC to 35ºC (50ºF to 95ºF) with the maximum rate of change not to exceed 10°C per hour. Shipping -40ºC to 70ºC (-40ºF to 158ºF).
® Product Overview Intel Server System R1000RP Family TPS Parameter Limits Operating Support operation up to 3050m with ASHRAE class deratings. Shipping 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C). Operating Half sine, 2g, 11 mSec. Unpackaged Trapezoidal, 25g, velocity change is based on packaged weight. Packaged Product Weight: ≥ 40 to < 80. Non-palletized Free Fall Height = 18 inches. Palletized (single product) Free Fall Height = NA.
® Intel Server System R1000RP Family TPS 2.4 Product Overview System Features and Options Overview Figure 4. System Components Overview 2.4.1 Hot Swap Hard Drive Bay and Front Panel Options Figure 5. 3.5" Hard Drive Bay - 4 Drive Configuration Figure 6. 2.5" Hard Drive Bay - 8 Drive Configuration Revision 1.
® Product Overview 2.4.2 Intel Server System R1000RP Family TPS Back Panel Features Figure 7. Back Panel Feature Identification (Redundant Power Supply as Shown) 2.4.
® Intel Server System R1000RP Family TPS 2.5 Product Overview Server Board Overview The chassis is mechanically and functionally designed to the standard form factor and half width server board, including Intel® Server Board S1200V3RP. The following sections provide an overview of the server board feature sets. The following figures show the layout of the server boards with each connector and major component identified. ® Figure 9. Intel Server Board S1200V3RPS Revision 1.
® Product Overview Intel Server System R1000RP Family TPS ® Figure 10. Intel Server Board S1200V3RPO and S1200V3RPM 10 Intel order number: G91532-003 Revision 1.
® Intel Server System R1000RP Family TPS Product Overview 2.5.1 Rear Component View The following figure shows the layout of the server board with each connector and major component identified. The description is given below in the table. A 2.5.1.1 Description Serial A port F Description Diagnostic LED B Display port (only for R1208RPMSHOR) G ID LED C DB15 Video out H Status LED D NIC port (RJ45) I USB connectors (USB 2.0) E NIC port (RJ45) J USB connectors (USB 3.0) ® Figure 11.
Product Overview ® Intel Server System R1000RP Family TPS Figure 13. Installing Front Bezel 2.
® Intel Server System R1000RP Family TPS 3. Power Subsystem Power Subsystem This chapter provides a high level overview of the power management features and specification data for the power supply options available for this server product. Specification variations are identified for each supported power supply. There are two power supply options available in Intel® Server System R1000RP Family: 350W fixed power supply and 450W redundant power supply.
® Power Subsystem Intel Server System R1000RP Family TPS Figure 14. 350W AC Power Supply Unit Enclosure Drawing 3.1.2 Power Supply Module Efficiency The power supply operates with efficiency ≧ 85% under 20% and 100% loads, ≧88% under 50% loads which are shown in the following table at 115V or 230V AC input voltages, 25°C. Table 4. Output Load for Efficiency Test Output 20% Load (A) 50% Load (A) 100% Load (A) +3.3V 1.3 3.4 6.8 +5V 2.2 5.5 10.9 +12V1 2.2 5.4 10.8 +12V2 2.2 5.4 10.
® Intel Server System R1000RP Family TPS Power Subsystem Cable Type Amperage Rating SJT 13 A Voltage Rating 125 V Figure 15. AC Power Cord 3.1.4 AC Input Requirement 3.1.4.1 Power Factor The PF shall align with server energy star 2.0 requirements. Power supplies must meet the minimum power factor requirements presented in the table below, for all loading conditions where the output power is greater than or equal to 75 watts. Table 6. Power Factor Output power Power factor 3.1.4.2 20% load 0.
® Power Subsystem Intel Server System R1000RP Family TPS dielectric strength criteria. If the working voltage between primary and secondary dictates a higher dielectric strength test voltage, the highest test voltage should be used. In addition, the insulation system must comply with reinforced insulation as per safety standard IEC 950. Separation between the primary and secondary circuits, and primary to ground circuits, must comply with the IEC 950 spacing requirements. 3.1.4.
® Intel Server System R1000RP Family TPS Power Subsystem Duration 1 to 12ms Sag 100% AC Line Sag (10sec interval between each sagging) Operating AC Voltage Line Frequency Performance Criteria Nominal AC Voltage ranges 50/60Hz No loss of function or performance > 12ms >30% Nominal AC Voltage ranges 50/60Hz Loss of function acceptable, self recoverable Table 9.
® Power Subsystem 3.1.4.13 Intel Server System R1000RP Family TPS Surge Immunity The power supply shall be tested with the system for immunity to AC Ring Wave and AC Unidirectional Wave, both up to 2kV. The power supply shall operate normally without any component damage under any condition. BI-WAVE 12Ω±2.0kV (Common mode) 2Ω±1.0kV (Differential mode) RING-WAVE 500A±2.0kV (Common mode) 500A±1.0kV (Differential mode) 3.1.4.
® Intel Server System R1000RP Family TPS Power Subsystem cycle OFF for 15sec (with +5VSB/0.1A) and a PSON# cycle HIGH for one second shall be able to reset the power supply. 3.1.6.1 Over Current Protection (OCP) Each output shall have individual OCP protection circuits. The PSU shall shut down and latch off after an over current condition occurs. Whereas OCP of +5VSB shall turn the power supply into “hiccup mode” until the OCP condition is removed.
® Power Subsystem Intel Server System R1000RP Family TPS designed to plug directly to the output connector of the power supply and it contains two DC/DC power converters to produce other required voltages: +3.3V and +5V. The PDB is integrated in the power supply cage. 3.2.1 Mechnical Overview The following drawing is the cage which integrates the power supply units and the PDB. Figure 16. 450W AC PSU with PDB Figure 17.
® Intel Server System R1000RP Family TPS Power Subsystem Figure 18. 450W AC Power Supply – Connector View 3.2.2 Power Supply Module Card Edge Connector This 450W AC power supply module has 2x14 card edge output connection that plugs directly into a matching slot connector on power distribution board. The connector provides both power and communication signals. Figure 19. 450W Power Supply Module Output Power Connector The following table defines the connector pin-out. Table 14.
® Power Subsystem Intel Server System R1000RP Family TPS 3.2.3 Power Supply Module Efficiency The following table provides the required minimum efficiency level at various loading conditions. These are provided at three different load levels: 100%, 50%, and 20%. Table 15. 450WAC Power Supply Efficiency Loading Minimum Efficiency 100% of maximum 88% 50% of maximum 92% 20% of maximum 88% 3.2.
® Intel Server System R1000RP Family TPS Power Subsystem Table 17. AC Input Voltage Range PARAMETER MIN RATED VMAX Voltage (110) 90 Vrms 100-127 Vrms 140 Vrms Voltage (220) 180 Vrms 200-240 Vrms 264 Vrms Frequency 47 Hz 50/60 63 Hz Start up VAC 85VAC +/4VAC Power Off VAC 70VAC +/5VAC Notes: 1. 2. 3. 3.2.5.3 Maximum input current at low input voltage range shall be measured at 90VAC, at maximum load.
® Power Subsystem 3.2.5.6 Intel Server System R1000RP Family TPS AC Inrush The peak inrush current must not damage the PSU, or the input fuse must not blow under any conditions of load, temperature, and input voltage, including repeated, rapid cycling of the power line. Half cycle peak inrush current, peak repetitive input current, and worse case power factor must be provided by the vendor to assist with the UPS and line conditioning, sizing, and selection.
® Intel Server System R1000RP Family TPS Power Subsystem Table 20. Performance Criteria Level A Description The apparatus shall continue to operate as intended. No degradation of performance. B The apparatus shall continue to operate as intended. No degradation of performance beyond spec limits. C Temporary loss of function is allowed provided the function is self-recoverable or can be restored by the operation of the controls. 3.2.5.
® Power Subsystem Intel Server System R1000RP Family TPS 3.2.6 DC Output Specification 3.2.6.1 Output Power/Currents The following table defines the output current ratings. Each output has a maximum and minimum current rating shown in Table 21. The power supply shall meet both static and dynamic voltage regulation requirements for the minimum dynamic load conditions. The power supply must meet only the static load voltage regulation requirements for the minimum static load conditions. Table 21.
® Intel Server System R1000RP Family TPS 3.2.7.2 Power Subsystem Over Voltage Protection (OVP) The power supply over voltage protection should be locally sensed. The power supply must shut down and latch off after an over voltage condition occurs. This latch shall be cleared by toggling the PSON# signal or by an AC power interruption. The following table contains the over voltage limits. The values are measured at the output of the power supply pins.
® Thermal Management Intel Server System R1000RP Family TPS 4 Thermal Management The fully integrated system is designed to operate at external ambient temperatures of between 10ºC and 35ºC with limited excursion based operation up to 35ºC.
® Intel Server System R1000RP Family TPS 4.2 Thermal Management Thermal Management Overview In order to maintain the necessary airflow within the system, all of the previously listed components and top cover need to be properly installed. For best system performance, the external ambient temperature should remain below 35ºC and all system fans should be operational. The system is designed for fan redundancy when the system is configured with two power supplies.
® Thermal Management Intel Server System R1000RP Family TPS does not change them. 4.2.2 Altitude This option is used to select the proper altitude that the system will be used in. Available settings include [300m or less], [301m-900m], [901m-1500m], and [Above 1500m]. Selecting an altitude range that is lower than the actual altitude the system will be operating at, can cause the fan control system to operate less efficiently, leading to higher system thermals and lower system performance.
® Intel Server System R1000RP Family TPS Thermal Management On-board Ethernet Controller Temperature Sensors3, 5 Add-In Intel® SAS/IO Module Temperature Sensors3, 5 PSU Thermal Sensor3, 8 CPU VR Temperature Sensors3, 6 DIMM VR Temperature Sensors3, 6 BMC Temperature Sensor3, 6 Global Aggregate Thermal Margin Sensors 7 I/O module Temperature Sensor (With option installed) Intel® ROC Module (With option installed) Notes: 1. For fan speed control in Intel® chassis 2.
® Thermal Management 4.3 Intel Server System R1000RP Family TPS System Fans Two managed dual rotor 40mm x 56mm system fans and one 40mm x 40 mm system fan provide the primary airflow for the system. Figure 22. System Fan Identification Each system fan is mounted inside its own plastic fan housing which includes rotational vibration dampening features. The fan assemblies are held in place by fitting them over mounting pins coming up from the chassis base. Figure 23.
® Intel Server System R1000RP Family TPS Thermal Management Fan speed for each fan is controlled by integrated platform management as controlled by the integrated BMC on the server board. As system thermals fluctuate high and low, the integrated BMC firmware will increase and decrease the speeds to specific fans to regulate system thermals. Each fan has a tachometer signal that allows the integrated BMC to monitor its status.
® Thermal Management Intel Server System R1000RP Family TPS Table 24. System Fan Connector Pin-out Pin 1 2 3 4 4.4 Signal Name Ground 12V Fan Tach Fan PWM Type GND Power In Out Description Ground is the power supply ground. Power supply 12 V. FAN_TACH signal is connected to the BMC to monitor the fan speed. FAN_PWM signal to control fan speed.
® Intel Server System R1000RP Family TPS System Storage and Peripheral Options 5 System Storage and Peripheral Options The Intel® Server System R1000RP product family has support for many storage device options, including: Hot Swap 2.5” Hard Disk Drives Hot Swap 3.5” Hard Disk Drives SATA Optical Drive Support for different storage and peripheral device options will vary depending on the system SKU. This section provides an overview of each available option. 5.1 2.
® System Storage and Peripheral Options Intel Server System R1000RP Family TPS Table 26. Drive Activity LED States Condition Power on with no drive activity Power on with drive activity Green Power on and drive spun down Power on and drive spinning up Drive Type SAS LED stays on Behavior SATA LED stays off SAS LED blinks off when processing a command SATA LED blinks on when processing a command SAS LED stays off SATA LED stays off SAS LED blinks SATA LED stays off 5.1.1 2.
® Intel Server System R1000RP Family TPS System Storage and Peripheral Options 5.1.2 Cypress* CY8C22545 Enclosure Management Controller The backplane supports enclosure management using a Cypress* CY8C22545 Programmable System-on-Chip (PSoC*) device. The CY8C22545 drives the hard drive activity/fault LED, hard drive present signal, and controls hard drive power-up during system power-on. 5.2 3.5” Hard Disk Drive Support The server is available with support for four 3.
System Storage and Peripheral Options 5.2.1 ® Intel Server System R1000RP Family TPS 3.5” Drive Hot-Swap Backplane Overview On the front side of each back plane are mounted four hard disk drive interface connectors (A), each providing both power and I/O signals to attached hard disk drives. Figure 31. The Front Side of 4 x 3.5” Hot Swap Backplane On the backside of each backplane are several connectors. The following illustration identifies each.
® Intel Server System R1000RP Family TPS System Storage and Peripheral Options 5.2.2 Cypress* CY8C22545 Enclosure Management Controller The backplanes support enclosure management using a Cypress* CY8C22545 Programmable System-on-Chip (PSoC*) device. The CY8C22545 drives the hard drive activity/fault LED, hard drive present signal, and controls hard drive power-up during the system power-on. 5.
Storage Controller Options Overview ® Intel Server System R1000RP Family TPS 6 Storage Controller Options Overview The server platform supports many different embedded and add-in SATA/SAS controllers to provide a large number of possible storage configurations. This section provides an overview of the different options available. 6.1 Embedded SATA Controller Support There are six 6Gb/s SATA ports on the motherboard. Intel® RSTe SW RAID through onboard SATA connectors provides SATA RAID 0/1/10/5.
® Intel Server System R1000RP Family TPS Front Control Panel and I/O Panel Overview 7 Front Control Panel and I/O Panel Overview On the front panel of all system configurations is a Control Panel providing push button system controls and LED indicators for several system features, and an I/O Panel providing USB ports and a video connector. This section describes the features and functions of both front panel options. 7.1 I/O Panel Features Label A Description USB ports Figure 35.
® Front Control Panel and I/O Panel Overview Label D E Description NIC-3 Activity LED System Cold Reset Button Intel Server System R1000RP Family TPS Label I J Description NIC-4 Activity LED NIC-2 Activity LED Figure 36. Front Control Panel Features A – System ID Button w/Integrated LED: Toggles the integrated ID LED and the Blue server board ID LED on and off. The System ID LED is used to identify the system for maintenance when installed in a rack of similar server systems.
® Intel Server System R1000RP Family TPS Front Control Panel and I/O Panel Overview Table 27. System Status LED State Definitions Color Off State System is not operating Criticality Not ready Green Solid on Ok Green ~1 Hz blink Degraded system is operating in a degraded state although still functional, or system is operating in a redundant state but with an impending failure warning Revision 1.3 1. 2. 3. 4. Description System is powered off (AC and/or DC). System is in EuP Lot6 Off Mode.
Front Control Panel and I/O Panel Overview Color Amber State ~1 Hz blink Criticality Non-critical System is operating in a degraded state with an impending failure warning, although still functioning Amber Solid on Critical, nonrecoverable – System is halted ® Intel Server System R1000RP Family TPS Description Non-fatal alarm – system is likely to fail: 1.
® Intel Server System R1000RP Family TPS Front Control Panel and I/O Panel Overview Table 28. Power/Sleep LED Functional States State Power Mode LED Description Power-off Non-ACPI Off System power is off, and the BIOS has not initialized the chipset. Power-on Non-ACPI On System power is on. S5 ACPI Off Mechanical is off, and the operating system has not saved any context to the hard disk. S4 ACPI Off Mechanical is off. The operating system has saved context to the hard disk.
® ® Intel Local Control Panel Intel Server System R1000RP Family TPS 8 Intel®Local Control Panel The Intel® Local Control Panel option (Intel® Product Order Code – AXXLCPANEL) utilizes a combination of control buttons and LCD display to provide system accessibility and monitoring.
® ® Intel Server System R1000RP Family TPS Intel Local Control Panel When the system’s status is degraded, the corresponding active event will be displayed in place of the banner. During an error, the background color will be light amber in color. The LCD panel displays the event with the highest severity that is most recent and is currently active (that is, in an asserted state). For the case that there are multiple active events with the same severity, the most recent event will be displayed.
® ® Intel Local Control Panel 8.3 Intel Server System R1000RP Family TPS Event Menu In the Event menu, the LCD displays the following items. It displays all active error events in human readable text in chronological order. Informational events are not displayed. There is no upper limit on the number of active events which can be displayed. The severity of the event will be indicated as any, Degraded, Non Fatal, or Fatal. ^ | <- | -> | Figure 41.
® Intel Server System R1000RP Family TPS ® Intel Local Control Panel This is a leaf node and there is no further traversal below this menu. User can only go to the previous screen by selecting the item ^. This applies to all the items of View menu. 8.4.2 System Information (SysInfo) Selecting SysInfo item in the View menu displays the server’s name, model, GUID, asset tag, and custom string. It is also a leaf node like above menu. The blanks in the following display will be replaced by their values.
® ® Intel Local Control Panel Intel Server System R1000RP Family TPS ^ | DHCP (or Static) | IP Address: xxx.xxx.xxx.xxx | Subnet Mask: xxx.xxx.xxx.xxx | Gateway: xxx.xxx.xxx.xxx Figure 46. LCP – RMM4 IP Configuration 8.4.5 Power Selecting Power item in the View menu displays the amount of AC power drawn by the system in Watts. ^ | xx W Figure 47. LCP – Power Consumed by the System Currently 8.4.
® Intel Server System R1000RP Family TPS ® Intel Local Control Panel ^ | IP Source | IP Address | Subnet | Gateway Figure 51. LCP – BMC IP Configuration Menu Selection of the IP Source in the above menu leads to the following screen. Based on the user’s selection in the following menu, the firmware sets the BMC IP source as either DHCP or Static. ^ | DHCP | Static Figure 52.
® ® Intel Local Control Panel Intel Server System R1000RP Family TPS 7. The Enter button is used to select a position at the first time and to leave the position at the second time. The following state transition diagram explains the above steps pictorially while setting an IP address using the LCD device. After entering an IP address, the user has to select Set item to set the entered IP address to the corresponding parameter (IP Address, Subnet Mask, or Gateway).
® Intel Server System R1000RP Family TPS ® Intel Local Control Panel ^ | Server Name | Server Model | Error | BMC IP | RMM4 IP | Power | Last PC | Custom String | Custom Logo Figure 56. Banner Configuration Menu Each of the menu items are explained below: Server Name: Displays the value specified in the product name in the product FRU information in the main board BMC FRU. The Server Name is the default banner.
® PCIe Support and Riser Card Support Intel Server System R1000RP Family TPS 9 PCIe Support and Riser Card Support Intel® Server System R1304RPOSHBN, R1208RPOSHOR, and R1208RPMSHOR provide one PCI Express* x16 slot through one riser card. Intel® Server System R1304RPSSFBN provides one PCI Express* x8 slot through one riser card. 9.1 Architectural Overview of the Server Board Riser Slots The following table lists the PCI Express* slot on the three motherboards and the mapping to the systems. Table 29.
® Intel Server System R1000RP Family TPS PCIe Support and Riser Card Support Figure 57. PCIe SLOT Drawing Revision 1.
PCIe Support and Riser Card Support ® Intel Server System R1000RP Family TPS Figure 58. 1U Riser Card Drawing You can get the installation steps from the Intel® Server System R1000RP Family Service Guide to assemble the add-in video card. 56 Intel order number: G91532-003 Revision 1.
Appendix A: Integration and Usage Tips ® Intel Server System R1000RP Family TPS Appendix A: Integration and Usage Tips Before attempting to integrate and configure your system, you should reference this section, which provides a list of useful information. After the system is integrated with processors, memory, and peripheral devices, the FRUSDR utility must be run to load the proper Sensor Data Record data to the integrated Server Management subsystem.
® Appendix B: POST Code LED Decoder Intel Server System R1000RP Family TPS Appendix B: POST Code LED Decoder As an aid to assist in troubleshooting a system hang that occurs during a system’s Power-On Self Test (POST) process, the server board includes a bank of eight POST Code Diagnostic LEDs on the back edge of the server board.
® Intel Server System R1000RP Family TPS Appendix B: POST Code LED Decoder Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh. The following table provides a list of all POST progress codes. Table 31.
® Appendix B: POST Code LED Decoder Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED # #7 #6 #5 #4 #3 #2 #1 #0 96h 1 0 0 1 0 1 1 0 97h 1 0 0 1 0 1 1 1 98h 1 0 0 1 1 0 0 0 99h 1 0 0 1 1 0 0 1 9Ah 1 0 0 1 1 0 1 0 9Bh 1 0 0 1 1 0 1 1 9Ch 1 0 0 1 1 1 0 0 9Dh 1 0 0 1 1 1 0 1 A1h 1 0 1 0 0 0 0 1 A2h 1 0 1 0 0 0 1 0 A3h 1 0 1 0 0 0 1 1 A4h 1 0 1 0 0 1 0 0 A5h 1 0 1 0 0 1 0 1 A6h 1 0 1 0 0 1 1 0 A7h 1 0 1 0 0 1 1 1 A8h 1 0 1 0 1 0 0 0 A9h 1 0
® Intel Server System R1000RP Family TPS Appendix B: POST Code LED Decoder Table 32.
® Appendix B: POST Code LED Decoder Intel Server System R1000RP Family TPS Table 33.
® Intel Server System R1000RP Family TPS Appendix C: POST Code Errors Appendix C: POST Code Errors Most error conditions encountered during POST are reported using POST Error Codes. These codes represent specific failures, warnings, or are informational. POST Error Codes may be displayed in the Error Manager display screen, and are always logged to the System Event Log (SEL). Logged events are available to System Management applications, including Remote and Out of Band (OOB) management.
Appendix C: POST Code Errors Error Code 0146 0191 0192 0194 0195 0196 0197 5220 5221 5224 8130 8131 8132 8133 8160 8161 8162 8163 8170 8171 8172 8173 8180 8181 8182 8183 8190 8198 8300 8305 83A0 83A1 84F2 84F3 84F4 84FF 8500 8501 8520 8521 8522 8523 8524 8525 8526 8527 8528 8529 852A 852B 852C 852D 852E 852F 8530 8531 8532 8533 64 ® Intel Server System R1000RP Family TPS Error Message PCI out of resources error Processor core/thread count mismatch detected Processor cache size mismatch detected Process
® Intel Server System R1000RP Family TPS Error Code 8534 8535 8536 8537 8538 8539 853A 853B 853C 853D 853E 853F (Go to 85C0) 8540 8541 8542 8543 8544 8545 8546 8547 8548 8549 854A 854B 854C 854D 854E 854F 8550 8551 8552 8553 8554 8555 8556 8557 8558 8559 855A 855B 855C 855D 855E 855F (Go to 85D0) 8560 8561 8562 8563 8564 8565 8566 8567 8568 8569 Error Message Appendix C: POST Code Errors DIMM_G3 failed test/initialization DIMM_H1 failed test/initialization DIMM_H2 failed test/initialization DIMM_H3 fai
Appendix C: POST Code Errors Error Code 856A 856B 856C 856D 856E 856F 8570 8571 8572 8573 8574 8575 8576 8577 8578 8579 857A 857B 857C 857D 857E 857F (Go to 85E0) 85C0 85C1 85C2 85C3 85C4 85C5 85C6 85C7 85C8 85C9 85CA 85CB 85CC 85CD 85CE 85CF 85D0 85D1 85D2 85D3 85D4 85D5 85D6 85D7 85D8 85D9 85DA 85DB 85DC 85DD 85DE 85DF 85E0 85E1 66 ® Intel Server System R1000RP Family TPS Error Message DIMM_D2 encountered a Serial Presence Detection (SPD) failure DIMM_D3 encountered a Serial Presence Detection (SPD)
® Intel Server System R1000RP Family TPS Error Code 85E2 85E3 85E4 85E5 85E6 85E7 85E8 85E9 85EA 85EB 85EC 85ED 85EE 85EF 8604 8605 8606 92A3 92A9 A000 A001 A002 A003 A100 A421 A5A0 A5A1 A6A0 Appendix C: POST Code Errors Error Message DIMM_L2 encountered a Serial Presence Detection (SPD) failure DIMM_L3 encountered a Serial Presence Detection (SPD) failure DIMM_M1 encountered a Serial Presence Detection (SPD) failure DIMM_M2 encountered a Serial Presence Detection (SPD) failure DIMM_M3 encountered a Ser
® Appendix C: POST Code Errors Intel Server System R1000RP Family TPS Integrated BMC Beep Codes The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are common across all Intel® server boards and systems that use same generation chipset are listed in the following table.
® Glossary Intel Server System R1000RP Family TPS Glossary Term ACPI Advanced Configuration and Power Interface AP Application Processor APIC Advanced Programmable Interrupt Control ASIC Application Specific Integrated Circuit ASMI Advanced Server Management Interface BIOS Basic Input/Output System BIST Built-In Self Test BMC Baseboard Management Controller Bridge Circuitry connecting one computer bus to another, allowing an agent on one to access the other BSP Bootstrap Processor Byt
® Intel Server System R1000RP Family TPS Term Glossary Definition IP Internet Protocol IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface IR Infrared ITP In-Target Probe KB 1024 bytes KCS Keyboard Controller Style LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode LPC Low Pin Count LUN Logical Unit Number MAC Media Access Control MB 1024KB MCH Memory Controller Hub MD2 Message Digest 2 – Hashing Algorithm MD5
® Glossary Term SEEPROM Intel Server System R1000RP Family TPS Definition Serial Electrically Erasable Programmable Read-Only Memory SEL System Event Log SIO Server Input/Output SMI Server Management Interrupt (SMI is the highest priority nonmaskable interrupt.
® Intel Server System R1000RP Family TPS Reference Documents Reference Documents Refer to the following documents for additional information: 72 Intel® Server Board S1200V3RP Technical Product Specification ACPI 3.0: http://www.acpi.info/spec.htm IPMI 2.0 Data Center Management Interface Specification v1.0, May 1, 2008: www.intel.com/go/dcmi PCI Bus Power Management Interface Specification 1.1: http://www.pcisig.com/ PCI Express* Base Specification Rev 2.0, Dec 06: http://www.