Specification Update
Monthly Specification Update
30.
Unable to get Server Management variables on BTP using SysCfg
Problem Server Management Settings cannot be configured using latest SysCfg Version
10 Build6 on S1200BTL.
Implication The user can’t change BMC setting by the latest syscfg tool on Intel
®
Server
Board S1200BTL.
Status Fixed in BIOS Rev.35.
Workaround None.
31.
Function key cannot work on KVM remote console on S1200BTL board
Problem Function key can not work on KVM remote console on S1200BTL board.
Implication The user can’t enter into BIOS setting from KVM remote console during server
is booting up.
Status Fixed in BIOS Rev.37.
Workaround Enter BIOS setting to set the option “System Boot Timeout” from 0 to 3
seconds.
32.
ME downgrade is not supported by IDA and OFU
Problem IDA and OFU can not support ME downgrade.
Implication IDA and OFU doesn’t support ME downgrade from 02.02.00.036 or higher
version to 02.00.09.032 or lower version.
Status May fix in the future IDA and OFU release.
Workaround None.
33.
When updating BMC in IDA, IDA shows BMC Release version in Hex. E.g.,
1.14 shown as 1.0e
Problem IDA can not show BMC version in decimalization.
Implication IDA only can show BMC release version in Hex when updating BMC by IDA
tool.
Status May fix in the future IDA release.
Workaround EFI shell can show BMC version correctly.
12