Technical Product Specification
Appendix B: Integrated BMC Sensor Tables Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Front Panel
Temperature
(Front Panel Temp)
21h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
PCH
TemperatureNote1
(PCH Temp)
22h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Baseboard
Temperature 3
(Inlet Temp)
24h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Hot-swap Backplane
Temperature
(HSBP Temp)
29h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Fan Tachometer
Sensors
(Chassis specific
sensor names)
30h–
34h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De
Analog R, T M –
Power Supply 1
Status
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 – Presence
OK
As and
De
–
Trig
Offset
A X
01 – Failure
Degraded
02 – Predictive
Failure
Degraded
03 – A/C lost
Degraded
06 – Configuration
error
OK
Power Supply 2
Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 – Presence
OK
As and
De
–
Trig
Offset
A X
01 – Failure
Degraded
02 – Predictive
Failure
Degraded
03 – A/C lost
Degraded
06 – Configuration
error
OK
40 Revision 2.4