Technical Product Specification
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 350W Power Subsystem
4.9
PMBus*
The PMBus* features included in this specification are requirements for ac/dc silver box power
supply for use in server systems. This specification is based on the PMBus* Specifications Parts
I and II, revision 1.1X3.
4.9.1
Related Documents
PMBus* Power System Management Protocol Specification Part I – General
Requirements, Transport and Electrical Interface, Revision 1.1X3.
PMBus* Power System Management Protocol Specification Part II – Command
Language, Revision 1.1X3 SMBus* 2.0.
4.9.2
Addressing
The power supply device address locations are shown below. For redundant systems, there are
two signals to set the address location of the power supply once it is installed in the system:
Address0 and Address1. For non-redundant systems, the power supply device address
locations should align with the Address0/Address1 location of 0/0.
Table 25. Power Supply Device Address Locations
PDB addressing Address0/Address1
0/0
0/1
1/0
1/1
Power supply PMBus* device
B0h
B2h
B4h
B6h
Note: Non-redundant power supplies use the 0/0 address locations.
Revision 2.4
23